B. THERMOPILE OUTPUT CHECK

(“B” Reading. Thermostat contacts OPEN - Main burner
OFF.)

1. Thermopile system - 500 millivolts minimum. If the

minimum millivolt reading is not obtainable, readjust
thermopile for maximum millivolt output. If  millivolt reading
is still below minimum specified, replace thermopile.

C. THERMOSTAT RESISTANCE CHECK

(“C” Reading. Thermostat contacts CLOSED - Gas valve
knob “ON”. Main burner should be ON.)

1. If the “C” reading drops more than 80 millivolts, the

resistance in the system is excessive and must be
reduced. To correct:

a. Clean and tighten thermostat leads and connections.

b. Shorten or replace theirmostat lead wires.

c. Cycle thermostat rapidly (manually turn dial) to clean
contacts.

D. AUTOMATIC PILOT DROPOUT CHECK

1. Hold gas valve knob depressed in pilot position until

maximum output is observed. Then extinguish pilot and
observe meter.

2. Dropout of automatic pilot magnet (sound should be

audible) should occur between 75 millivolts and 25
millivolts. If dropout occurs outside these limits, change
the valve.

MILLIVOLT CONTROL VALVE

To check Resistance of the gas valve, connect one wire
to the valve as shown.

1.

Resistance between the THTP & TH terminals
must be 11.5

±0.2

2.

Resistance between the THTP & TP terminals 
must be 10.0

±0.2

If resistance is outside of specifications listed, the gas
valve must be replaced.

BEFORE REPLACING THERMOPILE CHECK
MILLIVOLT READINGS

THERMOPILE READINGS

With all wires connected, with the pilot on and burners
off, the thermopile reading at the TP&THTP terminals
should be ~500mv. With the burners on, the millvolt
reading should be ~200mv.

WARNING AND OPERATING PLATES

All warning and operating plates on the Keating
MIRACLEAN

®

Griddle should be in place at all times. If

plates are damaged or lost, replace them immediately. 

12

Summary of Contents for 37399

Page 1: ...OUBLE SHOOT CHART 9 THERMOSTAT REMOVAL REPLACEMENT 10 11 SERVICE 10 12 WIRING DIAGRAM 13 CONTENTS IMPORTANT Keep a copy of your bill of sale The date on the bill establishes the warranty period should...

Page 2: ...ALLY LOSE ITS ODOR AND PRECAUTIONS SHOULD BE TAKEN TO ASSURE THAT PROPANE GAS IS NOT PRESENT EVEN THOUGH YOU DO NOT DETECT AN ODOR IF THERE IS ANY DOUBT YOU SHOULD CALL YOUR LOCAL PROPANE GAS SUPPLIER...

Page 3: ...RETURN DAMAGED MERCHANDISE TO KEATING FILE YOUR CLAIM AS ABOVE FIRST STEPS POSITIONING Keep appliance area free and clear of any combustibles Position the Miraclean Griddle 6 inches 152mm from any co...

Page 4: ...ure Refer to serial plate for proper gas requirement for your particular model FLEXIBLE GAS CONNECTORS AND QUICK DISCONNECT DEVICES For an appliance equipped with casters The installation shall be mad...

Page 5: ...te to determine if the burner is set up for the proper type gas before connecting the quick disconnect or piping from the building gas supply pipe a Gas pressure at manifold NATURAL GAS 4 0 in W C b G...

Page 6: ...food being cooked more rapidly than other griddle plates because the food is placed directly on the metal surface It is the understanding of this rapid heat transfer that permits the practical and be...

Page 7: ...ventional griddles at least start at lower temperatures You may be able to work the temperature up as you become accustomed to the more rapid cooking of the Miraclean Griddle 2 Cook as usual but after...

Page 8: ...clean surface is irreplacable NEVER USE A GRIDDLE STONE BRICK OR SCREEN TO CLEAN THE MIRACLEAN SURFACE DAMAGE DONE TO THE MIRACLEAN SURFACE BY GRIDDLE STONE BRICK OR SCREEN WILL VOID THE WARRANTY DO N...

Page 9: ...ition your griddle surface 1 Follow cleaning instructions on page 5 2 Heat the MIRACLEAN to 400 F for one hour 3 Lower thermostat to 350 F allowing the MIRACLEAN to cool to about 350 F as is evident w...

Page 10: ...T ELBOW 1 2 004194 14 ORIFICE HOLDER ASSEMBLY REFERENCE ONLY 15 FITTING 1 2 NPT MALE 000615 16 BURNER TUBE 1 2 X 9 1 800 KEATING 17 ELBOW 1 2 x 3 8 006477 18 GAS VALVE MILLIVOLT NATURAL GAS 023625 PRO...

Page 11: ...is in pilot position c Thermostat is not turned on d Low gas presssure e Gas valve failure a Put ON OFF switch to ON position b Turn knob to ON position c Turn thermostat to desired temperature d Set...

Page 12: ...NT 1 Lower the control panel by removing the screws 2 Disconnect the wires on the switch and remove switch 3 Snap the new switch into place and reconnect all wires 4 Return the control panel to its no...

Page 13: ...having a 1 1000MV range Conduct each check below by connecting meter test leads to terminals as indicated All readings are closed circuit A BURNER COIL CHECK A Reading Thermostat contacts CLOSED Gas...

Page 14: ...maximum output is observed Then extinguish pilot and observe meter 2 Dropout of automatic pilot magnet sound should be audible should occur between 75 millivolts and 25 millivolts If dropout occurs ou...

Page 15: ...13 GAS GRIDDLE WIRING DIAGRAM CONTROL PANEL THERMOSTAT ON OFF SWITCH...

Page 16: ...SE OR WARRANTY AGAINST LATENT DEFECTS E XCLUSIONS The warranties provided by Keating of Chicago Inc do not apply in the following instances 1 Defects arising out of or resulting from improper installa...

Page 17: ..._________________________________________________________ ADDRESS __________________________________________________________________________________________________________________ CITY ______________...

Reviews: