![KBR Multimess F96-***-5 Series Quick Manual Download Page 28](http://html1.mh-extra.com/html/kbr/multimess-f96-5-series/multimess-f96-5-series_quick-manual_659470028.webp)
Rev. 5.00
23892_EDEK
ZA0030-4318-1_EN
28
KBR multimess F96-...-5
6.9
Electrical connection
Connection elements
Screw terminals
Permissible cross-section
of the connecting cables
2.5 mm
2
Measure-
ment
voltage
inputs
Fuse protection
max. 1 A slow-blow
max. C2 automatic
isolating switch UL/IEC-approved
Measuring
current
inputs
Fuse protection
NONE!!!
Always short-circuit current transformer
terminals k and l prior to opening the circuit!
Input
control
voltage
Fuse protection
max. 1 A slow-blow
max. C2 automatic
isolating switch UL/IEC-approved
Relay
output
Fuse protection
max 2A medium time-lag
BUS
connection
Connection ma-
terial
For proper operation, please only use
shielded twisted-pair cables;
e.g. I-Y-St-Y 2x2x0.8
Pulse
output
Connection and
cables
Observe correct polarity!
For proper operation, please only use
shielded twisted-pair cables;
e.g. I-Y-St-Y 2x2x0.8
Transform-
er connec-
tion
Connections
See wiring diagram
Interfaces
Connec-
tion
RS485 BUS
connector pins
Terminal 90 ( )
Terminal 91 (A)
Terminal 92 (B)
6.10
Mechanical data
Switch-
board
installation
Housing dimen-
sions
96 x 96 x 65 mm (H x W x D)
Installation cut-out 92 x 92 mm
Weight
min. 300g, max. 350g, depending on optional board
Technical data