O p e r a t i n g I n s t r u c t i o n s
|
megaSun Tower Optima
30
Starts the aquaCool test (1 cycle).
㊶
AQUA
04/06
aquaCool start testcycle
> Start: press `+` for 2s
Starts the aquaCool endurance test. After having
selected and stored the “on” setting, you must
leave the service menu and start a tanning session.
Attention! aquaCool will continue to spray
permanently during a whole tanning session.
Factory setting: off
㊷
>
> on
> off
AQUA
05/06
aquaCool endurance test
Starts the aquaCool initialization process. A
spraying cycle of 90 seconds is started to
bleed the system before commissioning, after a
repair operation or after a canister replacement.
㊸
AQUA
06/06
aquaCool initialization
> Start: press `+` for 2s
Activates and deactivates the aroma function.
Factory setting: off
㊹
AROMA
01/07
Aroma
> on
> off
Reset -> after having exchanged the Aroma tin.
㊺
2 sec. = reset
AROMA
02/07
Aromastatus reset
> Reset: press `-` for 2s
Defines the aroma cycle time (spraying time +
spraying interval). Only active in systems without
aquaCool or disabled aquaCool. If „manual“ is
selected, by pressing the aquaCool- or Aroma plus
button a spray cycle can be triggered.
Factory setting: manuel
㊻
>
> manuel
> 1 .. . 5 (min)
AROMA
03/07
Cycle time
The cabinet scent release can be set at intervals,
controlled by a door contact switch, or completely
deactivated.
Factory setting: off
㊼
> Door contact >
> Intervall
> off
AROMA
04/07
Aroma cabin automatic
For interval operation of the cabinet scent released,
the number of scent releases per hour can be set
here.
Factory setting: 3
㊽
>
> 1 .. . 6
AROMA
05/07
Aroma cycles per hour