O p e r a t i n g I n s t r u c t i o n s
|
megaSun pureEnergy 5.0
38
4
②
If your Tower is equipped with a central
exhaust-air module, also undo the screw
②
that is located centrally at the top of
the door pane.
⇒
Lift the panes out of the guide rails and keep
them in a safe place.
INSTALLING ACRYLIC PANES
After the pane and the tubes (if necessary) have been
cleaned, reinsert the pane into the guide rails and
close the side covering strip.
Cleaning and replacing the
tubes
By regularly cleaning the tubes you can help pre-
serve their tanning power.
• When installing the tubes, make sure that the
tube inscription is visible. If it is installed in
a different position, there will be no tanning
effect.
• After new tubes have been installed, the
operating hours of the tubes must be reset in
the service menu.
REMOVING TUBES
4
90
0
ⓐ
ⓑ
Side
37
Removing acrylic panes.
⇒
Remove the tubes by turning each tube a
quarter to the right or to the left and then pull-
ing it out. Remove tubes from lower sockets
fi rst.