background image

OPERATING INSTRUCTIONS

Summary of Contents for megaSun pureEnergy 5.0

Page 1: ...OPERATING INSTRUCTIONS ...

Page 2: ......

Page 3: ...e do not accept any liability for nor do we guarantee the accuracy and or completeness of the information EXPORT Technical equipment and versions of the devices are in accordance with the legal prescriptions of the respective country of destination Export to the USA and Canada of the KBL products listed in this guide or operation of the systems in these countries are not permitted KBL does not acc...

Page 4: ...ions 13 Connections aquaCool box tower 13 Start up 14 Operating modes 14 Tanning instructions 15 Instructions for the user 15 Tanning times 16 Tanning mode 17 Starting the tanning session 17 Operation during the tanning session 17 Variable section of the control panel 18 Basic functions 18 Functions overview 19 Standby mode service mode 21 Layout of the display numbers 21 Switching the decorative ...

Page 5: ...acked and the parts inside must be transported individually to the place of installation e g using a dolly Depending on the weight of the components lifting them might require several people Old equipment disposal This device consists of components that cannot be thrown into the household garbage Dispose of your old equipment in an environmentally friendly manner after the end of its useful life M...

Page 6: ...r more and persons with more than 16 moles with a diameter greater than or equal to 2 millimetres If in doubt consult a phy sician Persons who had several severe sunburns as chil dren Persons with naturally red skin colour Persons who do not tan at all or cannot tan with out getting sunburn Persons who have a predisposition toward sun burn Furthermore this tanning unit has been designed for use by...

Page 7: ...rate the unit with the outer covers or acrylic panes removed The tanning system must be controlled via a timer that complies with the generally applicable stand ards Absolutely observe the maintenance frequencies indicated in the maintenance plan The tanning system operated in the circulating air mode may not be connected to an exhaust air sys tem Tanning times Adhering to tanning times and schedu...

Page 8: ...nning unit basically consists of the following components Two side parts comprising 12 tubes each Rear part including 14 tubes Door including 14 tubes Ceiling including fan and control element Base plate Casing of central exhaust air module optional equipment Door Door handle Ceiling grab handle with integrated control element Ceiling design element with integrated fan Top crown Rear wall Lateral ...

Page 9: ...pe the purpose of the ceiling fan is to cool down both the tubes and the client s body In this operation mode the appliance must not be connected to an exhaust air system The operation of the tanning system in circulating air mode is permitted only in rooms with adequate ventilation Please take notice of the information on the minimum room height Equipped with the optionally available central exha...

Page 10: ...staff The connection to the 400 V mains must be protected by fuses Their specifications are listed in the chapter Technical data A residual current operated circuit breaker RCD with short time delay is absolutely required KBL AG recommends the following type KBL 3200 0770 00 type Typ ABB F 204 A 40 0 03 AP R Should the operation of the tanning unit cause any interference in the power supply network...

Page 11: ... the SD card or you can record your own tracks to the SD card EXTERNAL AUDIO SOURCES As an external audio source you can connect devices ranging from the standard line level to low loudspeaker levels These sources comprise Studio music External bluetooth players EXTERNES 100 V MUSIKSIGNAL AM STUDIOKANAL OPTION Zum Anschluss an ein 100 V Audiosystem wird zum übertragen des Audiosignales ein 100V Üb...

Page 12: ...tandby and during tanning mode Make sure that you are within the recep tion area about 2 meters Make sure that your device is configured to search for other bluetooth devices Should this not be the case enable blue tooth manually To do so please read the instructions for your appliance Depending on your settings the search will be performed automatically or manually All available bluetooth devices ...

Page 13: ...re com patibility Due to the large number of manufacturers KBL can not guarantee a 100 compatibility In rare cases it may happen that a bluetooth connection can not be established CORRECTIVE ACTION Each unit offers a list of paired devices Delete the older entries in this list which have a profile that over laps with the ones for which you want to pair your device Start the bluetooth device detecti...

Page 14: ...e Operating Instructions in a place that allows for easy access at any time Operating modes The three different operating modes are explained below STANDBY MODE The unit is in an idle state i e it is connected to the mains but is currently not being used The tubes and the tanning lamps are switched off From the standby mode you can change over to the tanning mode or to the service mode TANNING MOD...

Page 15: ...rmissible tanning times It is essential to avoid this UV radiation from the sun or from UV devices can cause irreversible skin or eye dama These biolog ical effects depend on the type and amount of ra diation as well as on the individual sensitivity of the skin In cases of pronounced individual sensitivity or allergic reactions to UV radiation a physician should be con sulted before beginning tann...

Page 16: ...laced according to the maintenance intervals stipulated in the section dealing with maintenance EU TANNING SCHEDULE according to UV Type III and 0 3W m2 in compliance with EN 60335 2 27 Skin type I II III IV V VI 1 Session 6 min 6 min 6 min 6 min 6 min 6 min 2 Session 6 min 7 min 7 min 8 min 10 min 11 min 3 Session 7 min 7 min 9 min 10 min 14 min 17 min 4 Session 7 min 8 min 10 min 12 min 19 min 2...

Page 17: ... tanning ses sion can be started manually at any time by press ing the START button Operation during the tanning session You can control the functions of the device via the control panel during the tanning session It is particularly easy for you to access the basic functions Buttons with recesses that can easily be sensed allow for easy operation of the system even with your eyes closed NOTES 20 s...

Page 18: ...f you wish to make any changes you can do so in the variable section of the control panel By pressing one of the arrow buttons above or below the changeover symbol all available functions will be displayed one after the other according to the rotation principle You can switch these individual functions on or off and if possible make changes to the settings Variable section of the control panel Bas...

Page 19: ...the aquaCool function is deactivated automatically and the symbol shown below is displayed aquaCool is automatically re activated as soon as a full canister has been connected Volume max on min off Body fan The body fan is auto matically controlled by ACS As soon as you press one of the fan buttons the automatic mode is interrupted Keep pressed for 2 seconds megaVoice aquaCool manual control Alter...

Page 20: ... than one channel is available MP3 external In order to play tracks from your own Bluetooth music devices select the audio source MP3 external on the solarium control panel and start playback on the external player Use the corresponding operating elements of the external player in order to select the desired tracks Channel Channel MODEL ACTIVATING AUDIO FUNCTIONS S E L E C T ACTIVATE AUDIO FUNCTIO...

Page 21: ...ocated double functions In addition to the standard operating elements they stand for numbers that in standby mode provide access to standby and service functions Simply enter the corresponding sequence of numbers on the display 1 2 3 4 5 0 9 8 7 6 Switching the decorative lighting on and off 5 0 5 NOTE The connection times of the decorative lighting can be set in the service menu individually for...

Page 22: ...unctions on and off and to modify values Press 3 STORE to save all modifications made in all menu items Press 8 EXIT to go back to the previous menu level or to exit the service menu R E S E T ON STORE UP EXIT ENTER DOWN OFF RESET SERVICE MENU BASIC OPERATION The service menu is divided into the main menu and subordinate groups of functions If you choose a menu item e g AUDIO you will get access to...

Page 23: ... not take over the changes you made See also chapter Service Menu Timeout By pressing the STORE button you save all changes you have made in all menu items 3 By pressing 8 EXIT you go back to the previous menu level or you exit the service menu 8 SERVICE MENU TIMEOUT After performing your last operating action you have 2 minutes left to save the changes you have made Then a prompt appears and all ...

Page 24: ...lume adaption Dynamic volume adaption Treble MP3 USB High bass MP3 USB Low bass MP3 USB Volume adaption Studio Line In Treble Studio Line In High bass Studio Line In Low bass Studio Line In AQUA aquaCool aquaCool spray time Cycle time aquaCool start test cycle aquaCool endurance test aquaCool start initialization AROMA Aroma Aroma status reset Cycle time Aroma cabin automatic Aroma cycles per hour...

Page 25: ...tions In order to avoid operating errors read through the basics at the begin ning of the Service Menu section Always remember to save your settings by pressing STORE All menu items that comprise further submenus are displayed in CAPITAL LETTERS Sets the language of the menu Factory setting German German English ENVIRONMENT 01 05 Language Sets the contrast of the display Factory setting 00020 0000...

Page 26: ... Saturday A ON B ON A OFF B OFF Sunday A ON B ON A OFF B OFF Switching cycle A Switching cycle B Friday 08 30 12 00 14 30 22 00 A ON A OFF B ON B OFF ENVIRONMENT 04 05 TIMER DEKOLIGHT press ENTER Entering switching times for the decorative lighting The submenu is invoked by pressing START ENTER SELECT WEEK OR DAY OF THE WEEK ENTER SWITCHING TIME SET SWITCHING CYCLES ENVIRONMENT TIMER 01 04 Day AON...

Page 27: ...bes Save settings by pressing STORE Not available in this system 0156h 2 sec reset HOUR METERS 03 04 Operating hours collagen tubes Indicates the number of tanning sessions sunbaths and includes a reset function 2 sec reset HOUR METERS 04 04 Number of sunbaths 0000 Reset press for 2s Under the menu item PRESELECTION you can make the initial settings for the device The functions must be available a...

Page 28: ...al Activates and deactivates the voice guidance system megaVoice Factory setting on on off AUDIO 02 22 megaVoice Fixes the language setting of the megaVoice system The following languages are fully supported GB RU DE FR IT PL CZ NL HU BG HR RO RS SK The following languages are supported in part DK EE LT NO ES SE TR without easyCare Factory setting Depending on the operator country English German A...

Page 29: ...AUDIO 08 22 Number of studio channels If this function is active music is played nonstop i e also out of tanning sessions Factory setting off on off AUDIO 09 22 Music nonstop Allows for choosing the permanent audio source for the Music nonstop function Factory setting MP3 internal MP3 internal Studio Line In AUDIO 10 22 Nonstop music source Sets the volume for the tanning mode Factory setting 6 0 ...

Page 30: ... you can adapt the volume of studio line in signal Factory setting 00 dB 29 29 dB AUDIO 19 22 Volume adaption Studio Line In Sets the treble for studio music operation Factory setting 14 dB 14 14 dB AUDIO 20 22 Treble Studio Line in Sets the high bass for studio music operation Factory setting 08 dB 14 14 dB AUDIO 21 22 High bass Studio Line in Sets the low bass for studio music operation Factory ...

Page 31: ...ning session Attention aquaCool will continue to spray permanently during a whole tanning session Factory setting off on off AQUA 05 06 aquaCool endurance test Starts the aquaCool initialization process A spraying cycle of 90 seconds is started to bleed the system before commissioning after a repair operation or after a canister replacement AQUA 06 06 aquaCool initialization Start press for 2s aqu...

Page 32: ...Factory setting 2 1 9 AIR CONDITIONING 02 02 Start level body fan Not available in this system Note For devices with LED technology the desired RGB color mode is adjusted by the colorMotion controller RGB 01 01 RGB mode EASYCARE 01 03 SETTINGS press ENTER Not available in this system UV LEVEL 01 01 SET UV LEVEL These settings must only be made by trained service personnel Loads the factory default...

Page 33: ...th START ENTER Displays the current firmware typ variant SERVICE 04 11 FIRMWARE TYP press enter Submenu call with START ENTER Displays the cur rent firmware version of the system components Do not operate the system with different firmware versions All system components must be equipped with an identical firmware version SERVICE 05 11 FIRMWARE VERSIONS press enter Submenu call with START ENTER Display...

Page 34: ...2 Service mode with tanning Start press ENTER for 2s Show the characteristics of the device Configuration code Variant code Serial number SERVICE 09 11 SOLARIUM IDENTIFICATION press enter Branches to further configuration options These settings must only be made by trained service personnel SERVICE 10 11 SOLARIUM X CODE PIN Performs a restart of the electronics SERVICE 11 11 Reboot Reboot press for ...

Page 35: ...s then move away from the two buttons To cancel match press down the match code button on the LED controller and the O button at the RF controller at the same time wait for the LED lamp flashing several times then move away from the two buttons The LED controller is located in the rear wall of the tower colorMotion controller Decorative lighting On Off Program selection switch colorWheel Brightness...

Page 36: ...LIC PANES For cleaning the acrylic panes use the special cleansing agent and disinfectant megaClean sup plied by KBL and dilute it in water at a ratio of 1 13 VARNISHED AND PLASTIC PARTS To clean the varnished and plastic surfaces use a damp soapy cloth Do not clean the big plastic parts with a dry cloth This might scratch the surfaces To clean the PMMA plastic surfaces of the door and the mirror ...

Page 37: ... without any further auxiliary equipment The assembly is basically carried out in reverse order of the disassembly Exceptions are specifically pointed out Removing and cleaning the acrylic panes The panes are cleaned whenever necessary When cleaning the inside it is recommended to clean also the tubes The instructions for cleaning and care must be observed The outer surface can be cleaned without a...

Page 38: ...rails and close the side covering strip Cleaning and replacing the tubes By regularly cleaning the tubes you can help pre serve their tanning power When installing the tubes make sure that the tube inscription is visible If it is installed in a different position there will be no tanning effect After new tubes have been installed the operating hours of the tubes must be reset in the service menu R...

Page 39: ...he tower PH2 SD Please refer to the chapter Technical data for information regarding supported card sizes as well as file system and MP3 formats The card contains two directories Pop and Voice Within the Pop directory you can add or delete audio files as you please These audio tracks are played if the corresponding source has been selected The number of files is limited by the storage capacity of the...

Page 40: ...aCool canister is empty corresponding messages are displayed and aquaCool switches off shortly afterwards Unscrew the lid Keep the hose end including the lid in a clean plas tic bag while replacing the canister Replace the canister Start aquaCool initialization service menu Attach the cover 4 Screw the cover Replacing the aquaCool nozzles After 1000 hours of operation the aquaCool nozzles have to ...

Page 41: ...k replace 15 Error no access to the SD card Update via SD card failed access error SD card check replace 17 Parameter storage not found please connect and restart Parameter storage not found please connect and restart Check connector parameter storage If neces sary replace parameter storage 18 Parameter storage no valid serial number Parameter storage no valid serial number Contact your Customer S...

Page 42: ...cknowledge the message by pressing START If the fault persists contact your Customer Service 213 SD card missing No SD card in the audio module Insert an original SD card See chapter Recording to an SD card Removing the SD card 214 SD card unreadable SD card defective incompatible con tent Insert a new original SD card Acknowledge the message by pressing START See chapter Re cording to an SD card ...

Page 43: ... height of the room 2406 mm Applies to circulating air mode and operation mode with optional central exhaust system Electrical connection values Protective class IP 20 Mains voltage 400 V 3 N 50 Hz Wire cross section 5 x 2 5 mm2 Ölflex Fuses Automatic fuse K type safety cut out 3 pole 3x 20 A with residual current operated circuit breaker RCD Nominal power 8810 W Central exhaust air discharge optio...

Page 44: ...room height in circulating air mode and exhaust air mode 1395 mm 54 93 inches 2326 mm 91 58 inches 2406 mm 94 73 inches 1233 mm 48 55 inches 1843 mm 72 56 inches 2175 mm 85 63 inches 332 mm 13 07 inches Front view Top view RHS view door opened RHS view with central exhaust air module ...

Page 45: ...O p e r a t i n g I n s t r u c t i o n s megaSun pureEnergy 5 0 45 Remarks ...

Page 46: ...O p e r a t i n g I n s t r u c t i o n s megaSun pureEnergy 5 0 46 Remarks ...

Page 47: ......

Page 48: ...Ringstraße 24 26 56307 Dernbach Germany fon 49 0 26 89 94 26 0 fax 49 0 26 89 94 26 66 mail megaSun kbl de www megaSun de ...

Reviews: