O p e r a t i n g I n s t r u c t i o n s
|
megaSun 7000/7800 alpha
41
ERROR MESSAGES
After the error has been eliminated, all error messages must be acknowledged by pressing
START
on the interior control panel.
No.
Status message
Description
Remedy
01
Excess temperature bimetal
Bimetal switch triggers.
Check the air-intake/air-exhaust system. Let the tan-
ning device cool down.
02
Maximum tanning time!
Enabling signal from coin-box system
comes in longer than the time value
approved under “Maximum tanning time”
(voltage remains connected)
Disconnect from the coin-box system.
03
Excess temperature exhaust
fan, please check
Bimetal switch in the fan triggers.
Make sure the fan runs freely. Check the air-intake/
air-exhaust system. Let the tanning device cool down.
04
Connection fan speed con-
trol faulty
Faulty communication between Mainboard
and fan-speed control.
Check / replace the patch cable.
08
Canopy pane open, please
close
Contact of the canopy pane has triggered.
Close the canopy pane and check the contact.
09
Side pane open, please
close
Contact of the side pane has triggered.
Close the side pane and check the contact. If the fault
persists, contact your Customer Service.
10
Bench / bench pane open,
please close
Contact of the bench pane has triggered.
Close the bench / bench pane and check the contact.
11
Excess temperature bimetal
x-tra Tan
Bimetal switch in the shoulder tanner
triggers.
Check the ventilation system of the shoulder tanner.
Let the tanning device cool down. If the fault cannot be
eliminated in this way, contact your Customer Service.
12
KBL7 Hardware error
Input-Controller
Mainboard defective.
Contact your Customer Service.
13
Maximum write cycle flash
memory reached
Maximum write cycle flash memory
reached.
Contact your Customer Service.
14
Error! SD card read error
(CRC fault)
Update via SD card failed (CRC fault).
SD card check / replace.
15
Error! No access to the SD
card
Update via SD card failed (access error).
SD card check / replace
17
Parameter storage not
found, please connect and
restart
Parameter storage not found, please con-
nect and restart.
Check connector parameter storage. If necessary
replace parameter storage.
18
Parameter storage no valid
serial number
Parameter storage no valid serial number.
Contact your Customer Service.
19
CAN-BUS: Interior display
V1 is incompatible
CAN-BUS operators incompatible.
Use CAN-BUS operators V2.
20
CAN-BUS: preSelection dis-
play V1 is incompatible
21
CAN-BUS: audio module full
V1 is incompatible
22
CAN-BUS: RGB module V1
is incompatible
23
Parameter storage write
error
Parameter storage write error.
Check connector parameter storage. If necessary
replace parameter storage.
24
Parameter storage read error
Parameter storage read error.
Check connector parameter storage. If necessary
replace parameter storage.
25
Frequency detection: detec-
tion failed!
Frequency detection failed.
Restart the controller. Contact your Customer Service
after the third unsuccessful restart.
System messages
Summary of Contents for MegaSun 7000a
Page 1: ...OPERATING INSTRUCTIONS PRODUCT LINE ...
Page 2: ......
Page 48: ...O p e r a t i n g I n s t r u c t i o n s megaSun 7000 7800 alpha 48 Remarks ...
Page 49: ...O p e r a t i n g I n s t r u c t i o n s megaSun 7000 7800 alpha 49 Remarks ...
Page 50: ...O p e r a t i n g I n s t r u c t i o n s megaSun 7000 7800 alpha 50 Remarks ...
Page 51: ......