TEST OPERATION
The test operation must be carried out after the entire installation
has been completed.
Please confirm the following points before the test operation:
A protection feature prevents the air conditioner from being activated for
approximately 3 minutes when it is restarted immediately after shut off.
●
The indoor unit and outdoor unit are installed properly.
●
Tubing and wiring are correctly completed.
●
The refrigerant pipe system is leakage-checked.
●
The drainage is unimpeded.
●
The heating insulation works well.
●
The ground wiring is connected correctly.
●
The length of the tubing and the added stow capacity of the
refrigerant have been recorded.
●
The power voltage fits the rated voltage of the air conditioner.
●
There is no obstacle at the outlet and inlet of the outdoor and
indoor and indoor units.
●
The gas-side and liquid-side stop values are both opened.
●
The air conditioner is pre-heated by turning on the power.
According to the user’s requirement, install the remote controller
frame where the remote controller’s signal can reach the indoor
unit smoothly.
Test operation
●
Set the air conditioner under the mode of “COOLING” with the
remote controller, and check the following points per the
“Owner’s Manual”. If there is any malfunction, please resolve
it through chapter “Troubles And Causes” in the “Owner’s
Manual”.
●
The indoor unit
●
Whether the switch on the remote controller works well.
●
Whether the buttons on the remote controller works well.
●
Whether the air flow louver moves normally.
●
Whether the room temperature is adjusted well.
●
Whether the indicator lights normally.
●
Whether the temporary buttons works well.
●
Whether the drainage is normal.
●
Whether there is vibration or abnormal noise during operation.
●
Whether the air conditioner heats well in the case of the
HEATING/COOLING type.
●
The outdoor unit
●
Whether there is vibration or abnormal noise during operation.
●
Whether the generated wind, noise, or condensed water by the
air conditioner have influenced your neighborhood.
●
Whether any of the refrigerant is leaked.
CAUTION