Owner’s manual

 

13

 

 

Maintenance after a long period of non-use.

 

(e.g., at the beginning of the season)

 

 

Check and remove everything that might be blocking the    
inlet and outlet vents of indoor units and outdoor units.

 

 

Clean air filters and casings of indoor units.

 

Refer  to  "Cleaning  the  air  filter"  section  for  details  on  how    
to  proceed  and  make  sure  you  reinstall  the  cleaned  air        
filters in the same position.

 

 

Turn on the power at least 12 hours before you want to use 
the unit to ensure it works properly. As soon as the power is 
turned on, the remote controller displays appear.

 

 

Digital scroll central air conditioning 

auxiliary heating equipment

 

In winter, purchase the indoor unit with auxiliary heating to 
enlarge the capacity.

 

 

When turning to the heat mode the air conditioner with 
auxiliary heating will run at the set term.

 

 

Do not install the 4-way cassette type and duct/ceiling type 
(with auxiliary heating).

 

 
 

6.

 

POTENTIAL  PROBLEMS

 

 

Symptom 1: The system does not work

 

Symptom 3: White mist is expelled from the unit

 

Symptom 3.1: Indoor unit

 

 

When humidity is high during the cooling operation.  If the interior 
of  the  indoor  unit  is  extremely  contaminated,  the  temperature 
distribution  inside  a  room  becomes  uneven.  It  is  necessary  to 
clean the interior of the indoor unit. Ask your dealer for details on 
cleaning the unit, because a technician is required.

 

 

Symptom 3.2:  Indoor unit, outdoor unit

 

 

When the system is changed over to the heating operation after 
defrost operation. Moisture generated by defrost becomes steam 
and is exhausted.

 

 

Symptom 4: The air conditioner is noisy in

 

cooling mode

 

 

Symptom 4.1: Indoor unit

 

 

A continuous sound is heard when the system is in cooling mode 
or has stopped.

 

The drain pump (optional accessory) makes this sound.

 

 

A squeaking sound is heard when the system stops after heating 
operation.

 

The  expansion  and  contraction  of  plastic  parts  caused  by 
temperature change make this noise.

 

 

Symptom 4.2:  Indoor unit, outdoor unit

 

 

The air conditioner does not start immediately after pressing the 
ON/OFF button on the remote controller.

 

If the operation lamp lights, the system is in normal condition.    To 
prevent  the  compressor  motor  from  overloading,  the  air 
conditioner starts three minutes after it is turned on.

 

 

Heating  mode  is  running  when  the  following  lights  are  on: 
operation and the "PRE-DEF indicator (cooling and heating type) 
or the fan  only indicator (cooling only type)". When it starts but 
the  compressor  does  not,  the  indoor  unit  activates  protective 
measures because of the outlet temperature.

 

 

 

Symptom 2: Running fan mode during cooling 

mode

 

To  prevent  the  indoor  evaporator  frosting,  the  system  will 
change  into  fan  mode  automatically  before  resuming  cooling 
mode.

 

 

When the room temperature drops to the set temperature, the 
compressor goes off and the indoor unit changes to fan mode. 
When the temperature increases, the compressor starts again. 
It is same as in heating mode.

 

A continuous low hissing sound is heard when the system is in 
operation.

 

This is the sound of refrigerant gas flowing through both indoor 
and outdoor units.

 

 

A hissing sound which is heard at the start or immediately after 
stopping or defrosting.

 

This is the noise of refrigerant caused by a flow stop or flow      
change.

 

 

Symptom 4.3: Outdoor unit

 

 

The running noise may change due to a change in frequency.

 

 

Symptom 5: Dust comes out of the unit

 

When the unit is used for the first time in a long time. 
This is because dust has gotten into the unit.

 

 

Symptom 6: The unit gives off a strange odor

 

The unit can absorb the smell of rooms, furniture, and cigarette 
smoke, and then emit it.

 

 

Symptom 7: The outdoor unit fan does not

 

spin.

 

 

During operation. The speed of the fan is controlled to optimize 
how the product runs.

 

Summary of Contents for KAYF-22 DN3.0

Page 1: ...or purchasing our air conditioner Before using your air conditioner please read this manual carefully and keep it for future reference Caution The heating function of an indoor unit is available only when it is connected to a cooling heating outdoor unit ...

Page 2: ...DF 45 DN3 0 KPDF 56 DN3 0 KPDF 71 DN3 0 KPDF 80 DN3 0 KPDF 90 DN3 0 KPDF 112 DN3 0 KPDF 140 DN3 0 KPDHF 71 DN3 0 KPDHF 90 DN3 0 KPDHF 112 DN3 0 KPDHF 140 DN3 0 KPDHF 160 DN3 0 KPDHF 200 DN3 0 KPDHF 250 DN3 0 KPDHF 280 DN3 0 KPDHF 400 DN2 4 KPDHF 450 DN2 4 KPDHF 560 DN2 4 KPCF 56 DN3 0 KPCF 90 DN3 0 KPCF 140 DN3 0 KAYF 22 DN3 0 KAYF 28 DN3 0 KAYF 36 DN3 0 KAYF 45 DN3 0 KAYF 56 DN3 0 KAYF 80 DN3 0 K...

Page 3: ...ouch the air outlet or horizontal blades while the swing flap is in use because your fingers may become trapped or you might damage the unit Never put any objects into the air inlet or outlet Do not touch the fan with any object Do not inspect or service the unit yourself Ask a qualified service person to perform these tasks Do not dispose this product as unsorted waste It must be separately colle...

Page 4: ... may cause water leaks Do not touch the internal parts of the controller Do not remove the front panel Some internal parts may cause injury or be damaged Never expose little children plants or animals directly to the air flow Never expose children plants or animals directly to the air flow Do not allow a child to mount on the outdoor unit and don t place objects on it to avoid injury Falling or tu...

Page 5: ...nduced air Grille bolt lock Lock the air return grille Air deflector Control the blow out direction of the air Display panel Display status information and receive the remote controller signal Air Filter Filters dust Air Intake Intakeroomair Lock Buckle Closes the air intake grille Fig 2 8 Fig 2 5 High static pressure duct type Air Outlet Expels room air Heat Exchanger Exchanges cool air into warm...

Page 6: ...ype Fig 2 13 Air Outlet Outlet room air Heat Exchanger Exchange cool air into warm air Air Intake Intake room air here Fig 2 11 Indoor unit Air Outlet Connects the duct ControlBox Air Intake Intakes roomair Air Filter Filters dust Grounding Screw In the control box Fig 2 14 Connecting pipe Low pressure pipe Outlet pipe Console type Hi pressure pipe Inlet pipe Throttle part Electric control box Fig...

Page 7: ...ge The max temperature for the air conditioner Cooling Heating Table 3 1 Air intake Intake room air here Air filter Feet Lift up the air conditioner Filter the dust in the air Fig 2 17 Version III The vertical unit is concealed in the wall afterinstallation with air intake from the bottom and air delivery at thetop NOTE Air outlet Expels room air 1 Using the unit outside of the accepted range may ...

Page 8: ...downward air flow will cause condensation on the air outlet and louver surface Four way cassette type Cooling operation Adjust the louver horizontally Do not overcool or overheat Avoid excessive exposure to cold air as it is not healthy This applies especially to children the elderly and those with disabilities Heating operation Adjust the louver down Fig 4 1 Fig 4 2 To maintain a comfortable temp...

Page 9: ... that are too steep or water will drip from the unit Adjust the air flow up and down Cooling operation Adjust the louver horizontally The louver is horizontal When heating Adjust the louver down vertically Fig 4 6 Fig 4 7 Duct ceiling type The following section explains how to adjust the direction of air flow direction when the air outlet parts sold separately is used with the indoor unit When coo...

Page 10: ...Console type Adjust the air direction up and down Auto swing Press SWING for the louver will swing up and down automatically Manual swing Press Air Direction to fix the louver at the desired angle The louver swing will move up or down with each press 1 Water may drip from the surface of the unit or horizontal louver when cooling if the expel air direction is vertically down 2 The indoor temperatur...

Page 11: ...ront panel How to open the front panel Refer to Fig 5 4 Two way cassette type Fig 4 21 Before opening the front panel turn the machine off and turn the breaker to OFF Do not touch the metal parts on the inside of the indoor unit as it may cause injury Select the air flow as desired Please refer to Fig 7 2 for the positions When setting the air flow selection switch to Air conditioner automatically...

Page 12: ...l together with the air filter as shown in Fig 5 2 Pull the air in grill down to 45 and lift it up to remove the grill Do not try to adjust the louver by hand When adjusting it by hand the mechanism may not work properly or condensation may drip from air outlets 5 MAINTENANCE CAUTION Fig 5 1 1 Before you clean the air conditioner ensure it is powered off 2 Check that the wiring is undamaged andcon...

Page 13: ...ype Push the grill switches in the directions of the arrows Then open the air in grill downwards Press the claws on the right and left of the air filter down slightly then pull upwards For digital scroll floor standingtype The filter is housed in the lower part of the unit in versions II and III to take in air from below or from the rear to remove the filter in versions II and III do as follows Fi...

Page 14: ...nly operation for about half a day to dry the interior of the unit Clean the air filter and indoor unit casing Refer to Cleaning the air filter for details on how to proceed and make sure you install cleaned air filters back in the same position The air filter blocks dust If the filter is blocked the air conditioner will not work as well Clean the filter every two weeks when you use the unit is in...

Page 15: ...ing sound is heard when the system stops after heating operation The expansion and contraction of plastic parts caused by temperature change make this noise Symptom 4 2 Indoor unit outdoor unit The air conditioner does not start immediately after pressing the ON OFF button on the remote controller If the operation lamp lights the system is in normal condition To prevent the compressor motor from o...

Page 16: ...ts or stops frequently There is too much or too little refrigerant There is no gas in the refrigerating circuit Compressor is malfunction Voltage is too high or too low System circuit is blocked Check leakage and rightly recharge the refrigerant Vacuum and recharge the refrigerant Maintenance or the change compressor Install manostat Find reasons and the solution Low cooling effect The outdoor uni...

Page 17: ...e display disappears after a certain time Check whether the timer operation has come to an end when the TIMER OFF is indicated on the display The air conditioner operation will stop up to the set time The TIMER ON indicator goes off after a certain time Check whether the timer operation is started when the TIMER ON is indicated on the display Up to the set time the air conditioner will automatical...

Page 18: ...arm No address when powered on the first time Timer LED and run LED flash together After the fault ends the unit resumes automatically NO Type Contents Display content Remarks 1 Malfun ction Room temp sensor is abnormal E2 After the malfunctions disappear it restores automatically 2 Malfun ction Indoor outdoor unit communication is abnormal E1 After the malfunctions disappear it restores automatic...

Page 19: ...WP MDV03U 011SW 16127000000208 ...

Page 20: ......

Reviews: