Kaysun COMPAK KHP-15/190 ACS2 Owners & Installation Manual Download Page 5

DISPOSAL: Do not dispose this 

product as unsorted municipal 

waste. Collection of such waste 

separately for special treatment is 

necessary.

Do not dispose of electrical 

appliances as unsorted municipal waste, use 

separate collection facilities.Contact your 

local government for information 

regarding the collection systems available.

If electrical appliances are disposed of in 

landfills or dumps, hazardous substances 

can leak into the groundwater and get into 

the food chain, damaging your health and 

well-being.

After a long term use, check the unit base 

and fittings.

If damaged, the unit may sink and result in 

injury.

Arrange the drain pipe to ensure smooth 

draining.

Improper drainage work may cause wetting 

of the building, furniture etc.

Do not touch the inner parts of the controller.

Do not remove the front panel. Some parts 

inside are dangerous to touch, otherwise a 

machine malfunction may be caused.

Do not turn off the power supply.

System will stop or restart heating automati-

cally. A continuous power supply for water 

heating is necessary, except service and 

maintenance. 

If the unit has not been used for a long 

period of time(2 weeks or more), hydrogen 

gas will be produced in the water piping 

system.

Hydrogen gas is extremely flammable. To 

reduce the risk of injury under these 

conditions, it is recommended that open the 

hot water tap for several minutes at the 

kitchen sink before using any electrical 

appliance connected to the hot water system. 

When hydrogen is present, there will probably 

be an unusual sound such as air escaping 

through the pipe as the water begins to flow. 

There should be no smoking or open flame 

near the tap at the time it is open.

Confirm the safety of the installation area  

( walls, floors, etc. ) without hidden dangers 

such as water,  electricity, and gas. Before 

wiring/pipes.

Before  installation ,  check  whether  the  

user's  power supply meets the electrical 

installation requirements of unit  ( including 

reliable grounding ,  leakage ,  and wire 

diameter electrical load, etc.). If the electrical 

installation requirements of the product are 

not met, the installation of the product is 

prohibited until the product is rectified.

When installing multiple air conditioners in a 

centralized manner, please confirm the load 

balance of the three-phase power supply, 

and multiple units are prevented from being 

assembled into the same phase of the 

three-phase power supply. 

Product installation should be fixed firmly, 

Take reinforcement measures, when 

necessary. 

CAUTION

The earthing pole of socket must be 

grounded well, make sure that power 

supply socket and plug are dry enough 

and connected tightly.

How to check the power supply socket 

and plug are qualified?

Turn on power supply and keep the unit 

running for a half hour, then turn off 

power supply and plug out, check 

whether the socket and plug is hot or not. 

Before cleaning, be sure to stop the 

operation and turn the breaker off or pull 

out the power plug.

Otherwise, an electric shock and injury 

may be caused.

Water temperature over 50

 

can cause severe burns 

instantly from scalds.

Children, disabled and elderly

 are at highest risk of being 

scalded. Feel water before 

bathing or showering.

Water temperature limiting 

valves are recommanded.

Do not operate the unit with a wet hand.

An electric shock may be caused.

The installation height of power supply 

should be over 1.8m, if there is any water 

spattered, separate the power supply 

from water.

A one-way valve must be installed on the 

water inlet side, which is available from 

accessories, see manual "accessories" 

part.

It’s normal if some water drops from the 

hole of PT valve during operation. But, if 

there is a great amount of water, call your 

service agent for instructions.

2

Summary of Contents for COMPAK KHP-15/190 ACS2

Page 1: ...y much for purchasing our product Before using your unit please read this manual carefully and keep it for future reference COMPAK KHP 15 190 ACS2 Type Air source Heat Pump Water Heater OWNER S INSTAL...

Page 2: ...ole disconnection device which has at least 3mm separation distance in all pole and a residual current device RCD with the rating not exceeding 30mA shall be incorporated in the fixed wiring according...

Page 3: ...re of this manual When ordering repair parts please always give the following information 1 Model serial and product number 2 Parts name Front Cover Electronic Control Box Compressor Display Cover Ele...

Page 4: ...ker must be installed adjacent to the power supply Do not remove cover or deface any permanent instructions lables or the data label from either the outside of the unit or inside of unit panels Ask qu...

Page 5: ...ngers such as water electricity and gas Before wiring pipes Before installation check whether the user s power supply meets the electrical installation requirements of unit including reliable groundin...

Page 6: ...strong wind The base surface should be flat surface should be inclined no more than 2 and able to bear the weight of the unit and suitable for installing the unit without increasing noise or vibratio...

Page 7: ...ir flow As an example a room that has an 2 5 tall ceiling and is 3 meter long by 2 meter wide would contain 15m 2 5 Unit outline dimension unit mm 4 2 3 Maintenance space requirements unit mm Fig 2 1...

Page 8: ...o not dismantle the PT Valve Do not block off the drainage pipe It will cause explosion and injury if do not comply with the above instruction EXPLOSION Water inlet or outlet pipes The spec of the wat...

Page 9: ...connects to duct air outlet without duct 2 2 5 5 2 2 5 5 Straight line length m Bent pressure drop Pa Bent s qty Straight line pressure drop Pa m Duct Description Duct Round duct Rectangle duct 160 1...

Page 10: ...e pay attention to the drainage work we sugest to wrap the thermal insulated layer around ouside of the duct For the case of unit with duct the duct total length should be no more than 5m or the maxim...

Page 11: ...itch are optional 1 After inserting the weak current connection cable group secure the weak current connection cable group using the two cable ties on the right of the junction box see Fig 3 13 2 The...

Page 12: ...free of leaks Unit completely filled with water Water temperature limit valve or mixer tap recommanded installed per manufacturer s instructions Condensate Drain Line Installation Must be located wit...

Page 13: ...stop heat pump activate E heater to continually heat water to the target temperature If manually activate the E heater running when heat pump running E heater and heat pump will work together until th...

Page 14: ...ure is higher than 85 the TCO will automatically shut off the power of compressor and E heater After that it needs to be reset manually 1 2 3 4 4 2 4 Query function For the convenience of maintenance...

Page 15: ...htened otherwise will be extinguished E heat will be lightened when E heat is running otherwise will be extinguished Solar will be lightened when the machine is connected to the solar signal or connec...

Page 16: ...Adjust vacation days 1 360 days Switch to HYBRID mode Use this key to switch mode MODE CLOCK TIMER ON OFF DISINFECT No Icon Description 5 CLOCK CLOCK Press this button to enter the clock setting SET...

Page 17: ...corresponding value will decrease by pushing When setting temperature press more than 1s temperature value will be decreased continuously When Setting clock timer press more than 1s Clock timer value...

Page 18: ...con to add home appliance to your Comfort Home account Connected to the network Follow the insturctions in the app to set up the WiFi connection If the network connection fails please refer to the App...

Page 19: ...s not have electric heating function the heat pump available running ambient range is 7 43 if ambient tempera ture is out of range system will show above mentioned signal to let user notice it Q Why s...

Page 20: ...ture protection Tp 115 Protection active Tp 90 Protection inactive Maybe because of system blocked air or water or less refrigerant leakage in system after repair water temperature sensor malfunction...

Page 21: ...time please Shut off the power supply Release all the water in water tank and the pipeline and close all the valves Check the inner components regularly 7 2 Recommended regular maintenance table 7 1 M...

Page 22: ...d around outside of Aluminum microchannel heat exchanger Hydrophilic aluminum fin inner groove copper tube 28W 560 1787mm 3150W Max operating pressure 1 0MPa Water tank cap Water heating cap 1500W 390...

Page 23: ...is installed at least every 24 months 2 For equipment that contains fluorinated greenhouse gases in quantities of 50 tonnes of CO2 equivalent or more but of less than 500 tonnes of CO2 equipment at le...

Page 24: ......

Reviews: