Kaysun COMPAK KHP-15/190 ACS2 Owners & Installation Manual Download Page 17

No

Icon

Description

 6

 7

 CONFIRM/UNLOCK

If screen and buttons are unlocked, press it to 

upload setting parameters after setting any 

parameter: 

● If press it beyond 10sec, please resetting all

parameters.

If screen and buttons are locked, press it for 3s to 

unlock them.

TIMER

ON/OFF

TIMER

ON/OFF

TIMER

ON/OFF

Timer button 

Enter the 6-segment timing setting, 1ON 

icon  is always on, enter the TIMER ON 

setting, and the hour value flashes 

Confirm the hour value and enter the 

minute value setting

Confirm the minute value and enter the 

TIMER OFFsetting. At this time, 1OFF 

ICON is always on and the hour value is 

flashing 

Confirm hour and enter minute setting

Adjust minute value

Adjust hour value

Adjust hour value 

Confirm the minute value and complete 

the 1 st segment timer setting.

NOTE

1. During the setting process, press the time / ON/OFF 

key to enter the next ON/OFF setting 

2. In the process of setting, press time / ON/OFF to 

enter the next part of this segment

3. During the setting process, press the cancel key to 

cancel the timing operation being set and return to the 

main interface 

4. If there is any conflict in the setting time, the lastest 

set time shall prevail, and the previous period of timing 

will be cancelled automatically. If the set ON/OFF time 

are the same, this  of segment setting is invalid 

Adjust minute value

        DECREASE/DOWN

If screen is unlocked, corresponding value will 

decrease by pushing         

.

● When setting temperature, press         more 

than 1s, temperature value will be decreased 

continuously;

● When Setting clock/timer, press         more than 

1s, Clock/timer value will be decreased 

continuously;

● When setting vacation days, press         more 

than 1s, day value will be decreased continuously;

On querying, check items will page down by 

pressing         . 

            ON/OFF button and LED indicator

If unit is standby, press           , then unit will be OFF.

If unit is ON, press            , then unit will be OFF.

If unit is OFF, press             , then unit will be ON.

LED indicator          will be lightened if unit is ON or 

standby and extinguished if unit is OFF.

Icon

Description

 9

No

 8

5.3 Combination button

No.

Icon

Description

Sterilization 

time setting

+

MODE

+

MODE

Choose 01

Choose 03

Press the confirm key, the 

buzzer will give a short 

sound, and the unit will 

automatically clear the 

protection or error code

Press the confirm key to 

enter. At this time, the 

sterilization icon and the 

first two value of 8888 

light flash, indicating that 

the hour can be modified; 

after pressing the confirm 

key, the last two value of 

8888 light flash, indicating 

that the minutes can be 

modified. After setting, 

press OK to save the 

settings and exit. (press 

the Cancel button to exit 

the sterilization time 

setting) if the customer 

has not set the steriliza-

tion start time, carried out 

sterilization mode on 

23:00 defaultly,, once 

every 7 days; if the 

customer has set the 

sterilization start time, the 

sterilization will be carried 

out according to the 

sterilization start time set , 

once every 7 days.

Error code

14

Summary of Contents for COMPAK KHP-15/190 ACS2

Page 1: ...y much for purchasing our product Before using your unit please read this manual carefully and keep it for future reference COMPAK KHP 15 190 ACS2 Type Air source Heat Pump Water Heater OWNER S INSTAL...

Page 2: ...ole disconnection device which has at least 3mm separation distance in all pole and a residual current device RCD with the rating not exceeding 30mA shall be incorporated in the fixed wiring according...

Page 3: ...re of this manual When ordering repair parts please always give the following information 1 Model serial and product number 2 Parts name Front Cover Electronic Control Box Compressor Display Cover Ele...

Page 4: ...ker must be installed adjacent to the power supply Do not remove cover or deface any permanent instructions lables or the data label from either the outside of the unit or inside of unit panels Ask qu...

Page 5: ...ngers such as water electricity and gas Before wiring pipes Before installation check whether the user s power supply meets the electrical installation requirements of unit including reliable groundin...

Page 6: ...strong wind The base surface should be flat surface should be inclined no more than 2 and able to bear the weight of the unit and suitable for installing the unit without increasing noise or vibratio...

Page 7: ...ir flow As an example a room that has an 2 5 tall ceiling and is 3 meter long by 2 meter wide would contain 15m 2 5 Unit outline dimension unit mm 4 2 3 Maintenance space requirements unit mm Fig 2 1...

Page 8: ...o not dismantle the PT Valve Do not block off the drainage pipe It will cause explosion and injury if do not comply with the above instruction EXPLOSION Water inlet or outlet pipes The spec of the wat...

Page 9: ...connects to duct air outlet without duct 2 2 5 5 2 2 5 5 Straight line length m Bent pressure drop Pa Bent s qty Straight line pressure drop Pa m Duct Description Duct Round duct Rectangle duct 160 1...

Page 10: ...e pay attention to the drainage work we sugest to wrap the thermal insulated layer around ouside of the duct For the case of unit with duct the duct total length should be no more than 5m or the maxim...

Page 11: ...itch are optional 1 After inserting the weak current connection cable group secure the weak current connection cable group using the two cable ties on the right of the junction box see Fig 3 13 2 The...

Page 12: ...free of leaks Unit completely filled with water Water temperature limit valve or mixer tap recommanded installed per manufacturer s instructions Condensate Drain Line Installation Must be located wit...

Page 13: ...stop heat pump activate E heater to continually heat water to the target temperature If manually activate the E heater running when heat pump running E heater and heat pump will work together until th...

Page 14: ...ure is higher than 85 the TCO will automatically shut off the power of compressor and E heater After that it needs to be reset manually 1 2 3 4 4 2 4 Query function For the convenience of maintenance...

Page 15: ...htened otherwise will be extinguished E heat will be lightened when E heat is running otherwise will be extinguished Solar will be lightened when the machine is connected to the solar signal or connec...

Page 16: ...Adjust vacation days 1 360 days Switch to HYBRID mode Use this key to switch mode MODE CLOCK TIMER ON OFF DISINFECT No Icon Description 5 CLOCK CLOCK Press this button to enter the clock setting SET...

Page 17: ...corresponding value will decrease by pushing When setting temperature press more than 1s temperature value will be decreased continuously When Setting clock timer press more than 1s Clock timer value...

Page 18: ...con to add home appliance to your Comfort Home account Connected to the network Follow the insturctions in the app to set up the WiFi connection If the network connection fails please refer to the App...

Page 19: ...s not have electric heating function the heat pump available running ambient range is 7 43 if ambient tempera ture is out of range system will show above mentioned signal to let user notice it Q Why s...

Page 20: ...ture protection Tp 115 Protection active Tp 90 Protection inactive Maybe because of system blocked air or water or less refrigerant leakage in system after repair water temperature sensor malfunction...

Page 21: ...time please Shut off the power supply Release all the water in water tank and the pipeline and close all the valves Check the inner components regularly 7 2 Recommended regular maintenance table 7 1 M...

Page 22: ...d around outside of Aluminum microchannel heat exchanger Hydrophilic aluminum fin inner groove copper tube 28W 560 1787mm 3150W Max operating pressure 1 0MPa Water tank cap Water heating cap 1500W 390...

Page 23: ...is installed at least every 24 months 2 For equipment that contains fluorinated greenhouse gases in quantities of 50 tonnes of CO2 equivalent or more but of less than 500 tonnes of CO2 equipment at le...

Page 24: ......

Reviews: