52
53
WARNING
Switch off the power supply before opening the switch box service panel and making any changes to the DIP switch
settings.
High temperature curves for cooling mode
10.2 DIP switch settings overview
10.2.1 Function setting
DIP switch 13 is located on the hydraulic module main control board (see "9.3.1 main control board of hydraulic module") and
allows configuration of additional heating source thermistor installation, the second inner backup heater installation, etc.
DIP
switch
ON=1
OFF=0
Factory
defaults
DIP
switch
ON=1
OFF=0
Factory
defaults
S1
1
Reserved
Reserved
OFF
S2
1
Start outside
circulator pump
after six hours
will be invalid
Start outside
circulator pump after
six hours will be valid
OFF
2
With solar
energy
Without solar
energy
OFF
2
Without TBH
With TBH
OFF
3/4
0/0=Without IBH and AHS
0/1=With AHS for heat mode
1/0=With IBH
1/1=With AHS for heat mode
and DHW mode
3:OFF
4:OFF
3/4
0/0=variable speed pump
(Max head:8.5m)
0/1=constant speed pump
1/0=variable speed pump(reserved)
1/1=variable speed pump
(Max head:9m)
3:OFF
4:ON
10.3 Initial start-up at low outdoor ambient temperature
During initial start-up and when water temperature is low, it is important that the water is heated gradually. Failure to do so
may result in concrete floors cracking due to rapid temperature change. Please contact the responsible cast concrete building
contractor for further details.
To do so, the lowest water flow set temperature can be decreased to a value between 25°C and 35°C by adjusting the FOR
SERVICEMAN. Refer to "FOR SERVICEMAN/special function/preheating for floor".
10.4 Pre-operation checks
Checks before initial start-up.