12.7
T_DRYPEAK
The target peak temperature of water flow during
floor drying up
45
30
55
1
°C
12.8
START TIME
The start time of floor drying up
Hour: the
present time
(not on the
hour +1,on
the hour +2)
Minute:00
0:00
23:30
1/30
h/min
12.9
START DATE
The start date of floor drying up
The present
date
1/1/2000 31/12/2099 2001-1-1
d/m/y
13.1
AUTO RESTART
COOL/HEAT MODE
Enable or disable the auto restart cooling/heating
mode.0=NON, 1=YES
1
0
1
1
/
13.2
AUTO RESTART DHW
MODE
Enable or disable the auto restart DHW mode.
0=NON,
1=YES
1
0
1
1
/
14.1
POWER INPUT
LIMITATION
The type of power input limitation, 0=NON,
1~8=TYPE 1~8
0
0
8
1
/
15.1
CN12 ON/OFF
Define the CN12 port,0= REMOTE ON/OFF,1= TBH
ON/OFF
0
0
1
1
/
15.2
CN15 T1B
Enable or disable the T1B PROBE. 0=NON; 1=YES
0
0
1
1
/
15.3
CN35 SMART GRID
Enable or disable the SMART GRID. 0=NON; 1=YES
0
0
1
1
/
15.4
Ta PROBE
Choose the sensor of Ta. 0=HMI Ta on wired control-
ler;
1=IDU Ta connected on the main borad of indoor unit
0
0
1
1
/
64
65