High Speed Camera User Guide
45
12.4
Analog controls
𝑃 = (𝑃 + 𝐵𝑙𝑎𝑐𝑘𝐿𝑒𝑣𝑒𝑙) ∗ 𝐺𝑎𝑖𝑛
The GeniCam interface for this feature is described below:
Name
Interface
Values
Description
AnalogControl
Icategory
GainSelector
IEnumeration
DigitalAll
DigitalRed
DigitalGreen
DigitalBlue
Selects digital gain to control
Gain [GainSelector]
IFLoat
Specifies the gain. The gain
written to register is
GainAll*GainX, where X is the
color
AnalogGain
IEnumeration
1
2
4
8
Analog gain.
BlackLevelSelector
DigitalAll
DigitalRed
DigitalGreen
DigitalBlue
AnalogAll
Selects black level to control
BlackLevel
[BlackLevelSelector]
IFloat
-1024 to 1024
Controls the DC offset applied
to each channel. The value
written to register will be
All+Color.
If selected AnalogAll the
control is done with VOFF +
VOFF invert bit in SSI
BlackLevelAuto
IEnumeration
Off
DigitalOnce
DigitalContinuous
AnalogOnce
AnalogContinuous
Table 19 : Analog controls GeniCam names
Camera ISP specification