kawneer.com
Laws and building and safety codes gover
ning the design and use of glazed
entrance, window
, and curtain wall pr
oducts vary widely
. Kawneer does not contr
ol
the selection of pr
oduct configurations, operating har
dwar
e, or glazing materials,
and assumes no r
esponsibility ther
efor
.
Kawneer r
eserves the right to change configuration without prior notice when deemed
necessary for pr
oduct impr
ovement.
© Kawneer Company
, Inc., 2011
3
11/16"
11/16"
PANELINE
®
EXIT DEVICE
SERVICE INSTRUCTIONS
EC 97904-38
(PART NO. 038-371)
NOVEMBER, 2011
Install the top strike in the normal position with the marker arrow toward door stop (see sketches
below). The strike can be rotated for adjustment purposes, (1) space in and (2) spaces out from
normal point. Shim strike to accommodate top door clearance
SINGLE DOOR
PAIR OF DOORS
OF PAIR OF DOORS
NOTE: Position strikes with
marker arrow toward door stop.
PLAN VIEW - TRANSOM / HEADER
TOP STRIKE
INSTALLATION
THRESHOLD
INSTALLATION
SINGLE DOOR
PAIR OF DOORS
PLAN VIEW - BUTT HUNG THRESHOLD (OFFSET PIVOT SIMILAR)
BOTTOM LATCH BOLT
DOOR STOP
5/8" DIA.
HOLES
OF PAIR OF DOORS
USING 033-981 THRESHOLD STOP PACKAGE AS A
TEMPLATE, DRILL (2) 5/32" (0.156) DIAMETER HOLES
AND SECURE STOP WITH SELF TAPPING SCREWS.
APPROXIMATELY 1/32"
WITH WEATHERING
WITHOUT WEATHERING
FRAME PREPARATION AND STRIKE ADJUSTMENT
#26 (0.147) Drill
DOOR STOP
INSTALLATION
OF THRESHOLD
AND DOOR
SHIM
STRIKE
#8 THREAD
CUTTING SCREWS