kawneer.com
Laws and building and safety codes gover
ning the design and use of glazed
entrance, window
, and curtain wall pr
oducts vary widely
. Kawneer does not contr
ol
the selection of pr
oduct configurations, operating har
dwar
e, or glazing materials,
and assumes no r
esponsibility ther
efor
.
Kawneer r
eserves the right to change configuration without prior notice when deemed
necessary for pr
oduct impr
ovement.
© Kawneer Company
, Inc., 2011
13
PANELINE
®
EXIT DEVICE
SERVICE INSTRUCTIONS
EC 97904-38
(PART NO. 038-371)
NOVEMBER, 2011
PUSH PANEL AND
CHASSIS ASSEMBLY
FILLER PLATE
HINGE STILE
SCREWS "A"
(2) ON TOP -
(2) ON BOTTOM
SCREWS "A"
(2) ON TOP -
(2) ON BOTTOM
HEIGHT ADJUSTMENT SCREWS "B"
(2) ON TOP - (2) ON BOTTOM
LOCK STILE
FILLER PLATE
DEGLAZING TOOL
NOTE:
ALL SERVICE WORK STARTS WITH THE TURNING OR REMOVAL
OF THE (12) SCREWS MARKED "A" AND "B" ABOVE. THEY ARE
LOCATED UNDER THE OUTSIDE HORIZONTAL GLASS STOPS.
DOORS WITH GLASS THICKNESS OF 3/8" (9.5) OR LESS DO NOT
HAVE TO BE DEGLAZED FOR ACCESS TO THE SCREWS.
THICKER INFILLS DO HAVE TO BE DEGLAZED.
NOTE:
UNITS WITH FILLER PLATES LESS THAN 1-1/2" (38.1) WIDE HAVE
ONLY (1) SCREW "A" TOP AND BOTTOM ON EACH END.
1/16" Appro
ximately
(1.6)
1/16" Appro
ximately
(1.6)
Figure 3
Figure 4
INSTRUCTIONS FOR ADJUSTING PRE-1989 PUSH PANEL ASSEMBLY
CURRENT
PRE 1989
DOOR STILES