15
Calibrating the machine
The machine must be calibrated after replacing the spindle.
ARCTICA Test Body Set (order no. 1.009.6916):
▪ Titanium Milling Pin D 2 (Mat. no. 1.008.7097)
▪ Titanium Milling Pin D 0.5 (Mat. no. 1.008.7098 )
▪ Outside micrometer (Mat. no. 1.002.5839)
▪ Outside micrometer holder (Mat. no. 1.002.5840)
▪ KaVo ARCTICA C-Cast B70/20 (Mat. no. 1.008.7466)
▪ ARCTICA Tool magazine (Mat. no. 1.009.0718)
Blank for test body production: ARCTICA C-Cast-Blank (B70/20)
(Mat. no. 1.008.7466 )
15.1
Configuring the tool magazine
▶ Insert Titanium Milling Pin D 2 in position 1 in the tool magazine.
▶ Insert Titanium Milling Pin D 0.5 in position 5 in the tool magazine.
▶ Insert the tool magazine in the tool holder.
15.2
Inserting the blank
▶ Insert the ARCTICA C-Cast-Blank (B70/20) in tool holder until it reaches the
stop.
▶ Fix the blank in place using the universal tool (Mat. no. 1.009.0859) at a tor‐
que of 2 Nm.
15.3
Starting the test body programme
▶ Close the door of the ARCTICA Engine.
Technician's instructions KaVo ARCTICA Engine