FOR YOUR OWN SAFETY TURN OFF POWER AT MAIN FUSE BOX OR CIRCUIT BREAKER PANEL BEFORE
TROUBLESHOOTING YOUR FAN.
WARNING
!
10. Troubleshooting
Make sure main power is turned OFF.
WARNING
!
Make sure main power is turned OFF.
WARNING
!
TROUBLE
PROBABLE CAUSE
SUGGESTED REMEDY
1. Fan will not start.
1. Fuse or Circuit Breaker blown.
1. Check Main and Branch Circuit Fuses or Circuit Breakers.
2. Loose power line connections to the Fan.
2. Check line power connections to Fan.
3. Dead Battery in Remote Transmitter. 3.
Replace the Transmitter Batteries with New Batteries.
2. Fan sounds
1. Blades not attached to Fan.
1. Attach Blades to Fan before operating.
noisy.
2. Screws securing Fan Blades to
2. Check to make sure the Screws which attach the Blades to
Motor are loose.
the Motor are tight.
3. Loose Screws in Motor Housing.
3. Check to make sure all Screws in Motor Housing are snug.
(Not Over-Tight).
4. Loose Ceiling Cover, Hanger Bracket or
4. Check the Ceiling Cover and Hanger Bracket are tight on the
Electrical Outlet Box.
Electrical Outlet Box and the Box is tightly attached to the
building structure.
3. Fan wobbles
1. Set Screws in Motor Coupler are not
1. Raise Coupler Cover and tighten Set Screws securely.
excessively.
tightened securely.
2. Set Screw in the Hanger Ball/Downrod
2. Tighten the Setscrew in the Hanger Ball/Downrod
Assembly is loose.
Assembly.
3. Screws securing Fan Blades to Motor
3. Check to be sure Screws which attach the Fan Blades
are loose.
to the Motor are tight.
4. Fan Blades are not seated properly.
4. Check to be sure that the Screws securing the Fan
Blades seat firmly.
5. Hanger Bracket and/or Ceiling Outlet Box
5. Tighten the Hanger Bracket Screws to the Outlet Box,
is not securely fastened.
and/or secure Outlet Box.
6. Fan Blades out of balance.
6. Interchanging an adjacent (side by-side) Blade pair can
redistribute the weight and result in smoother operation.
Or use supplied Balancing Kit to balance Blades.
4. Light fixture will
1. Loose Electrical Connectors.
1. Shut off the Branch Circuit Electricity at the Main Fuse Box or
not illuminate.
Circuit Breaker Panel and check the Electrical Connectors for
proper installation.
2. Remote Control Battery is weak.
2. Replace the AAA Remote Control Batteries.