3 / 8
Shorten the inner
conductor to the speci
fi
ed
length, leaving no burrs.
Longer inner conductors
can lead to defects.
PG 11 adapter
19 ± 1
PG 1
1
Installation
Mount the ampli
fi
er vertically with the cable input facing down. Ensure suf
fi
cient air circulation around all sides.
Install correctly in accordance with EN 60728-11.
The connected network must be earthed in accordance with regulations, even if the ampli
fi
er has been removed.
Only quali
fi
ed personnel are permitted to perform servicing work.
- The speci
fi
ed torques must be adhered to for compliance with the electrical and mechanical data.
- Wall attachment to be performed using dowel screws with a thread diameter of 5-6 mm
Hexagon socket-head screw AF = 5 mm
Tightening torque M
A
= 5-6 Nm
Potential equalisation: Clamping range: 4-6 mm
2
Screw with Z2 cross-head and 1.2 slot
142
190
200
218
78.5
Distances from adjacent surfaces:
a)
≥
150 mm
b)
≥
50 mm
a)
a)
b)
b)
Current-carrying unit!
Always disconnect the power plug and switch off the remote feed prior to installation.
Safety regulations to EN 60728-11, EN 60065 and EN 60065 must be complied with.
Installation of the RF cable connection
fi
tting (VOS 139/RA)
When installing the RF cable connection
fi
ttings (PG 11), the
fi
tting manufacturer’s instructions should be complied with.
Safety instructions:
There may already be a remote feed voltage applied
to the RF cable!
Installation
procedure:
1) Completely unscrew the inner conductor clamp
2) Screw in the PG 11
fi
tting
3) Tighten the inner conductor clamp (M
A
= 1-1.2 Nm)
Required
tools:
- Screwdriver for socket-head screws 5 AF
(housing cover), M
A
: 5-6 Nm
- Screwdriver for socket-head screws 2 AF
(inner conductor clamp)
- Open-ended wrench 22 AF (PG 11
fi
tting)
If the cable inner conductor diameter is greater
than 1.2 mm, or in case of burr, the device sockets
may be destroyed.
Diameter
0.6 - 1.2 mm
burr free
Max. 2 mm protrusion
Tightening torque
3 Nm max. (do not
overtighten)