8 / 14
Note:
In PRBS mode you can set the COFMD parameter guard interval and code rate.
The CW mode can be used for output level measurement.
Main menu (display in the CW mode)
CW
Outp.
S21
306.00
MHz
----
“COFDM mode” sub-menu (for setting CW)
***
UFO333MX
***
Mode
CW
1.12
Selecting the COFDM parameters
In the
PRBS mode sub-menu
you can set the COFMD parameter guard interval and code rate. The parameters can only be selected
if
SAT-Sig
or
PRBS
operating mode has been selected.
The output signal parameters are selected using the “<” and “>” buttons and adjusted using the “+” and “-” buttons.
Main Menu
E1
1236
MHz
TP
27.500
MS/s
3/4
QPSK
Outp.
S21
306.00
MHz
8
MHz
QAM64
“QAM stage” sub-menu
***
UFO333MX
***
Mode
SAT Sig
Guard
1/32
Code rate
5/6
The following settings are available:
Guard
1/4, 1/8, 1/16, 1/32
Lower values permit higher data rates
Code rate
1/2, 2/3, 3/4, 5/6, 7/8
Higher values permit higher data rates at the cost of reduced error protection
1.13
Transport stream processor: Channel multiplex
Main Menu
E1
1236
MHz
P
TP
27.500
MS/s
3/4
QPSK
Outp.
S21
306.00
MHz
8
MHz
QAM64
“Transport stream processor” sub-menu
***
UFO333MX
***
Filter
0% /
0%
IDs
Back
The setting of the
channel multiplex “
fi
lter”
is performed in the
“TP”
(transport stream processor) sub-menu.
The
“TP”
transport stream processor is selected using the “<” and “>” buttons and the sub-menu is called up using the “Sub-menu”
button. This sub-menu can be exited only when the cursor is on the “Back” parameter. To do this, use the “<” and “>” buttons to select the
parameters “on” and “off” and press the “Sub-menu” button
to return to the main menu.
Note:
The Electronic Programme Guide (EPG) shows only the programmes that are available on the E1 input tuner.
This should be recognised when scheduling.