26
SAT
DiSEqC menu
See the technical appendix for DiSEqC command sets for EXR 20,
EXR 22 and 9xx series Kathrein matrices.
Note
COMMAND OVERVIEW FOR FRAMING BYTE
HEX
Byte
Description
E0
Master command, one-time transmission
E1
Master command, recurring transmission
E2
Master command, expecting response, fi rst transmission
E3
Master command, expecting response, recurring transmission
E4
Response from Slave, “OK”, no errors detected
E5
Response from slave, command not supported by slave
E6
Response from Slave, parity error detected
E7
Response from slave, command not recognised
COMMAND OVERVIEW FOR ADDRESS BYTE
Hex byte Description
00
All devices
10
Every LNB, matrix or SMATV
11
LNB
12
LNB with loop-through
14
Matrix (switcher)
15
Matrix (switcher) with loop-through
18
SMATV
20
Every polarizer
21
Maximum turn (full skew) in linear polarisation
22
Stepwise polarizer adjustment
30
Every positioner
31
Polar / Azimuth positioner
32
Elevation positioner
33
Combined positioner
34
LNB positioner
40
Installation help
41
Signal strength adjustment help
60
Reserved for assigned addresses
70
“Intelligent slave interface” for “Proprietary Multi-Master
bus”
71
Interface for participants and controlled head end
Fx
OEM expansion
The command set for activation of the EXR 22 Kathrein matrix has
been entered and sent.