52 of 56
Operating Instructions CAP 750
13.6 LED Status Indicator on the CAP Converter/
External Push-button
Function
LED
colour
Signal
Description
Error
Red
LED flashes 1 x for 0.5 second, then stops for 2 seconds
No connection to CAP
LED flashes 2 x for 0.5 second, then stops for 2 seconds
Satellite not found
LED flashes 3 x for 0.5 second, then stops for 2 seconds
Ignition is active
LED flashes 4 x for 0.5 second, then stops for 2 seconds
CAP is blocked
LED flashes 5 x for 0.5 second, then stops for 2 seconds
Operating voltage too low
LED flashes 6 x for 0.5 second, then stops for 2 seconds
Temperature warning
LED flashes 7 x for 0.5 second, then stops for 2 seconds
Transponder does not exist
To return the CAP converter to the normal operation:
1. Check the cause of error.
2. Press the push-button once to acknowledge the error in order for the CAP converter to operate
normally again.
Normal
operation
Green
LED flashes slowly
CAP is in the park position
LED flashes 3 x, then stops for a bit
CAP is moving to a position,e.g.
to the park position
LED flashes quickly
CAP searches for a satellite
position
LED is permanently on
Satellite is found
Red
LED is permanently on
Standby
USB
Update
Yellow
1)
LED is permanently on
Downloading file from USB
Green
LED is lit green for 1 second
Download successful
Red
LED is lit red for 1 second
Failed to download the file
Yellow
1)
LED is lit yellow for 1 second
Download complete
Boot-
loader
Yellow
1)
LED is permanently on
Bootloader is active
Red
LED flashes 1 x for 0.5 second, then stops for 2 seconds
Data carrier not found
LED flashes 2 x for 0.5 second, then stops for 2 seconds
Folder structure/Update file not
found
LED flashes 3 x for 0.5 second, then stops for 2 seconds
Invalid update file
LED flashes 4 x for 0.5 second, then stops for 2 seconds
File saving failed
1)
On the external push-button, the red and the green LEDs are on at the same time