Page 26
Katadyn
12
Installation options of EK systems
There are different options to install the EK system to an existing water pipe system.
Because the diameter of the tubes from the EK system is limited to 1”, the Electro Katadyn is installed as a
bypass device:
12.1
Sample System Layout
bypass
Waterpump
Filtration of
floating particle
(if needed)
Electro Katadyn unit
Electro Katadyn unit
Cistern
(Contamination time)
Bypass
waterflow
Valve to regulate
the mainflow
12.2
Sample System Layout
marine
Generator for
fresh water
(desalination)
Electro Katadyn unit
Electro Katadyn unit
Cistern for
fresh water
Bypass
waterflow
Valve to regulate
the mainflow
Calcium unit
or
water softening
(if installed)
Produced water
for drinking and
cleaning
12.3
Sample System Layout without bypass using direct flow
marine
Generator for
fresh water
(desalination)
Electro Katadyn unit
Electro Katadyn unit
Cistern for
fresh water
Mainflow
Calcium unit
or
water softening
(if installed)
Produced water
For drinking and
cleaning