Page 18
Katadyn
11
Commissioning of the Electro-Katadyn System EK-4 / EK-24
11.1
Basic components:
−
Control Cabinet
−
Activator with electrode system
−
Flow Switch
The bypass piping (main pipe) is not part of the Katadyn scope of supply. The bypass (“part-stream”)
principle is applied to keep the head loss low and is used in the case of larger flow volumes. The partial
flow diverted through the Electro-Katadyn System receives silver ions in proportionately higher
concentration. The silver dose needed is reached by subsequent mixing of the water in the common pipe
downstream of the Electro-Katadyn. Based on empirical data the following values serve as a guide for
expected flows through the EK:
EK 4:
0.5 m
3
/h
EK 2-6/24: 2.0m
3
/h
11.2
Environmental conditions
Check if the mounting position
corresponds to the environmental data in chapter
11.3
Short installing guide of the EK System
•
Mount the Activator body to a suitable place
•
Mount the Control Cabinet close to the activator body (activator cable length 1.2m)
•
Connect the inlet piping to the inlet of the activator (G3/4” EK-4, G1” EK-X/24)
•
Connect the outlet piping to the outlet piping of the activator (G3/4” EK-4, G1” EK-X/24)
•
Connect the drain piping to the drain outlet of the activator (G3/4” EK-4, G1” EK-X/24)
•
Wiring the Flow Switch, activator head, the Mains supply and all other optional instruments to the
Control Cabinet (see connection drawings 17.5 Electrical connection / 17.6 Electrical connection
Activator Anode/Cathode).
•
Remove screws from activator head.
•
Remove activator head
o
If silver anodes and cathodes are not installed, install them according chapter
•
Check that sealing ring is properly placed on activator head
•
Replace activator head on Activator body and screw in the screws (max 4Nm torque)
•
Pressurize the whole system and check for leaks.
Summary of Contents for EK-24
Page 1: ...ELECTRO KATADYN INSTRUCTION MANUAL EK 4 EK 24...
Page 16: ...Katadyn Page 15 Change to the screen Alarm History Change to the screen Trend...
Page 37: ...Page 36 Katadyn 17 4 Dimensions EK 24 300 400 140 G 1 G 1 235 400 400 160 240 50 65...
Page 41: ...Page 40 Katadyn 17 6 2 EK 24 Anode brown Cathode blue EK Control Cabinet X1 1 2 br bl...
Page 42: ...Katadyn Page 41 18 CE declaration of conformity...