10
Table 2
Saga-22
Saga-30
Fuel
Wood
Wood
Fire safety
Pass
Pass
Mean flue gas
temperature
421°C
410°C
Total heat output
16 kW
18 kW
Carbon monoxide
emissions at 13% O
2
0.25 %
0.65 %
Efficiency
70 %
70 %
Flue draft
12 Pa
12 Pa
Ignition load
6 Kg
7 Kg
Refuelling loads
4 + 2.5 Kg
4.5 + 4.5 Kg
Temperature class of
chimney
T
–
600
T
–
600
Safety distances to
combustible materials
Table 1
Table 1
Combustion gas
maximum
temperature
541.9 °C
522 °C
Surface temperature
Pass
Pass
Durability
Pass
Pass