WINTER STORAGE:  In regions where there is significant 

freezing in the wintertime, the fountain and light kit should 
be removed from the water to protect them from the 
expansion pressure of the ice.  In many areas, fountains 
will keep some amount of ice open through the winter.  
However, when the water is thrust into the air, it is exposed 
to the colder air temperatures longer and can actually make 
ice thicker on the pond/lake.  Storage over winter is best in 
a location that is out of the sun and cool, but above 32° F.  

CLEANING:  Fountains and light kits should be removed 
from the water at least once per year (at the end of the 
season in cold climates) to clean the exterior of the system, 
especially the stainless steel motor housing (can) and light 

fixtures.  The motor housing and light fixture surfaces  

dissipate heat into the water and any algae, calcium, etc. 
build-up will become an insulator that blocks heat transfer.  
In warmer regions it is recommended that the motor is 
removed and cleaned at least two to three times per year 
depending on conditions.  In most cases a power washer 

will be sufficient if the unit and algae are still wet.  Also 

make sure the lens of the light fixtures is clean to ensure the 

brightest light possible.

LIGHT PUCK REPLACEMENT:  The LED puck lights 
are sealed and do not require any maintenance other than 
cleaning.  If a kit fails to operate it can be removed. Only 
perform this removal/replacement with all equipment 
disconnected from the power source.  

Any required repairs need to be performed by Kasco 
Marine.  Any alterations or changes made to Kasco units 
by an unauthorized source will void the warranty.  This 
includes tampering with the unit, power cord, and/or 
control box.  Please contact Kasco Marine, Inc. at 
715-262-4488 
or [email protected].

5.  Upon installation of the assembled unit, connect 

your LED light kit to your field installed GFCI pro

-

tected outlet and timer.

Additional Color or Replacement Kits

If you wish to add a different color or need a 
replacement kit, these part numbers will include the 
8 puck light assembly with 3’ cord.  They will not 
include the junction box or main power cord leading 
to the control panel.  The 8 puck light assembly 
will connect to your existing junction box with the 
underwater connector.  See the section on Replacing 8 
Puck Lights for details.

LED8012W  White color 8 Puck LED assembly
LED8012R 

Red color 8 Puck LED assembly

LED8012B 

Blue color 8 Puck LED assembly

LED8012G 

Green color 8 Puck LED assembly

LED8012A 

Amber color 8 Puck LED assembly

Maintenance Recommendations

• 

 Under No Circumstances should anyone enter the 
water while a fountain is operating.

• 

Please keep the original box for maintenance shipping. 

The following maintenance procedures can be utilized to 
ensure many years of quality performance from your Kasco 
Fountain and Light Kit and reduce the need for more costly 
repair work.

PROPER INSTALLATION:  Proper installation of Kasco 
equipment will include a power source with ground fault 
protection.  For Fountain models, Kasco provided control 
panels included with the unit have built-in ground fault 
protection.  Ground fault interrupters are a safety feature 
that can also alert you to electrical leaks in the equipment.  
If you have repeat, consistent trips of the ground fault 
device, the equipment should be disconnected and removed 
from the water.  The power cord should be inspected for 
damage and you should contact your distributor, or call 
Kasco Marine at 715-262-4488 for further instructions or 
email Kasco at [email protected].

OBSERVATION:  Operating equipment should be observed 
on a regular basis (daily, if possible) for any reduction 
or variation in performance.  If a change in performance 
is observed, the equipment should be disconnected from 
power and inspected. 

Summary of Contents for LED8012

Page 1: ...sembly Instructions pg2 Additional Color or Replacement Kits pg4 Maintenance Recommendations pg4 Warranty Policy pg5 Replacing 8 Puck Lights pg6 Troubleshooting Tips pg6 Customer Repair Form pg7 Registration Information pg8 Rev 02 22 13 Kasco Marine Inc 800 Deere Rd Prescott WI 54021 PH 715 262 4488 FAX 715 262 4487 www kascomarine com ...

Page 2: ...specially cold water as in Spring Fall and Winter which poses a hazard itself NEVER lift or drag the fountain or light kit by the power cords If you need to pull the unit to the side of the pond use the anchoring ropes Do not use waders in ponds lakes that are deep with drop offs drastic slopes or soft bottom material Do not use a canoe or boat that tips easily during installation To reduce the ri...

Page 3: ...ream fountain Make sure these areas are clean free of debris and dry Remove the backing from one of the dual lock squares and stick to the bottom of one of the indents See Fig 2 Repeat to the other 7 indents of the float Fig 2 3 Place the puck light that has the power cord leading to the junction box in the indent on the float that has a notch for power cords This would be the same area where the ...

Page 4: ...on installation of the assembled unit connect your LED light kit to your field installed GFCI pro tected outlet and timer Additional Color or Replacement Kits If you wish to add a different color or need a replacement kit these part numbers will include the 8 puck light assembly with 3 cord They will not include the junction box or main power cord leading to the control panel The 8 puck light asse...

Page 5: ...rial or work manship under normal use and service The Kasco Marine Inc obligation under this warranty is limited to replacing or repairing free of charge any defective part within one 1 year from the date of shipment Customer shall pay ship ping charges for returning the unit to Kasco THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR IMPLIED AND ANY OTHER OBLIGATION OR LIABILITY WHATEV...

Page 6: ... should be bright again LED emitters out The 8 puck lights have a total of 48 led emitters 6 per puck to provide an overlapping sphere of illumination Over time you may see a few of the led emitters stop working If this occurs the light kit will continue to work without a noticeable difference in light output If you have more than a few emitters failing to illuminate and it impacts the illuminatio...

Page 7: ...r service that you may exclude it Please contact Kasco if in doubt Do not ship the control box with the unit for repair unless otherwise instructed Today s Date ___________________ Customer Information Name _________________ Phone Number _____________________ Address __________________________ Alternate Number ___________________ City ____________________ Email Address ______________________ State...

Page 8: ..._______ Serial Ex 2101LEDC8025 ____________________________ Purchase Date _____________________ Purchased From ___________________________________ Registration Date ___________________________ Kasco Marine Inc 800 Deere Rd Prescott WI 54021 Phone 715 262 4488 Fax 715 262 4487 www kascomarine com sales kascomarine com 884082 ...

Reviews: