CONTENTS

 

Safety Instructions ………………………………………………… 
General Owner’s Instructions & Unit Specs………………………. 
Quick Disconnect & Strain Relief Instructions……………………. 
Cord Sizing and Gland Selection …………………………………. 
EVFX & 2400EJF Parts Included, Tools Needed, & Pattern Sizes.. 
EVFX & 2400EJF Assembly Instructions…………………………. 
8400EJF & 3.1EJF Parts Included, Tools Needed, & Pattern Sizes 
8400EJF & 3.1EJF Assembly Instructions………………………… 
EAF and ECF Parts Included & Tools Needed……………………. 
EAF Assembly Instructions………………………………………... 
EVFX, EJF, & EAF Installation Instructions……………………… 
ECF Assembly & Installation Instructions………………………… 
Maintenance Recommendations…………………………………… 
Troubleshooting Tips………………………………………………. 
Contact Information………………………………………………... 

 

I. 

II. 

III. 

IV. 

V. 

VI. 

VII. 

VIII. 

IX. 

X. 

XI. 

XII. 

XIII. 

XIV. 

XV. 

 


4-5 

6-7 
8-9 

10-11 
12-13 

14 

15-16 

17 

18-20 

21 
22 
23 

Rev. 1/23/08 

Making a Splash! 

Summary of Contents for F2400EAF

Page 1: ...luded Tools Needed Pattern Sizes EVFX 2400EJF Assembly Instructions 8400EJF 3 1EJF Parts Included Tools Needed Pattern Sizes 8400EJF 3 1EJF Assembly Instructions EAF and ECF Parts Included Tools Neede...

Page 2: ...in operation It is NEVER recommended to enter the water with the equipment in operation Caution should be used when dealing with any electrical equipment with moving parts NEVER run the unit out of wa...

Page 3: ...are designed and engineered for continuous duty such as on fish farms or other aquacul ture applications or on demand use as needed in a recreational water feature During flotation operation the wate...

Page 4: ...land is orientated with the stepped edge facing the gland nut see picture top of next column STEP THREE Prepare the cable and strip wire ends as shown below STEP FOUR Insert the stripped wire ends int...

Page 5: ...t Kasco does not recommend adding more than 60m of cord to any unit The chart below shows the proper Gland to be used with different cord sizes The measurements are based on the Outside Diameter O D o...

Page 6: ...0EJF FOUNTAIN TOOLS SUPPLIES NEEDED A Anchors or stakes for installing unit 2 B 2 Phillips head screw driver C 240V Electrical Supply near pond on a post D Two 30cm pieces of 2 54cm galvanized pipe fo...

Page 7: ...zzle marked C1 on fin makes use of the collar marked C2 on the top rim and the 3 8 x 4 bolt Linden Display Produces a two tiered display with a center column 1 3 meters tall by 0 7 m wide and an outer...

Page 8: ...1 4 Phillips Pan Head Screws Part C and a 1 4 Flat Washer Part D to secure the float to the motor housing Insert screw with washer through bolt hole in float and into receptacle on the unit Tighten u...

Page 9: ...re the power cord to a molded hole in the float to prevent cord damage if there is no strain relief on the cord If a Strain Relief is present on the cord you may disregard the Nylon Tie On cords with...

Page 10: ...Diagram to Right 1 6 x 1 2 Phillip Pan Head Self Tapping Screw 3 2 3 8 x 4 bolt 1 3 Linden Nozzle 1 4 Redwood Nozzle Y Insert comes installed in 7 1 5 Juniper Nozzle 1 6 Willow Nozzle 1 7 Redwood Spr...

Page 11: ...n nozzle marked L inside one of the fins uses the 3 8 x 4 bolt LINDEN Model HP Height Width 8400EJF 2 4 7 10 4 3 1EJF 3 4 1 9 8 The Willow nozzle marked W on the inside of the cone uses the 3 8 x 4 bo...

Page 12: ...should now be extending through the assem bly Loosely install the six Lock Nuts Part B5 on the ends of the bolts do not tighten yet Connect the top and bottom brackets using three 1 4 x 3 4 Bolts Par...

Page 13: ...talled and seated properly into the nozzle Push the nozzle down over the cone assem bly it may require light taps with a rubber mallet to seat properly Next use the 3 Self Tapping Screws Part D1 provi...

Page 14: ...l 3 D 9 16 14mm 7 16 11mm Nut Driver E 9 16 14cm 7 16 11mm Socket F Adjustable crescent wrench Aerator Parts Included EAF Models A Aerator Unit with cord or stub cord 1 B1 Small Float Ring with two 50...

Page 15: ...the three bolts previously removed with the 3 hooks provided with the Bottom Screen making sure the hook passes through the screen just inside the top support ring of the screen not through the handl...

Page 16: ...e motor inside the float If a support object is used make sure the weight is supported on the cage not the propeller For Model 8400EAF the notch in the center of the Unit Mounting Bracket should be po...

Page 17: ...ired location in the pond lake secure the cord near power source to prevent it from being dragged into the wa ter Anchor the ropes or secure them to the shoreline so the ropes are free of slack but no...

Page 18: ...d two Stainless Steel Lock Washers Part B13 See photo above for orientation STEP FOUR Place one of the three Angle Brackets Part B4 perpendicular to the Base Strap at the front end of the Base Strap O...

Page 19: ...nt or back to the Draw Band itself it is reversi ble Orient the arm of the Draw Band so it aligns with the cord clamp on the cage of the motor housing and is parallel to the Angle Brackets attached in...

Page 20: ...STEP THIRTEEN Float the circulator in the water and position where desired Tie the front Rope to a stake on the shore or weight If a weight is used sink weight in front of unit so rope is taught Circu...

Page 21: ...owever when the wa ter is thrust into the air it is exposed to the colder air temperatures longer and can actually make ice thicker on the pond lake Storage over winter is best in a location that is o...

Page 22: ...n the unit off when it overheats Once the unit has cooled down it will start back up If you are noticing these symptoms the unit should be unplugged immediately because the Thermal Overload will conti...

Page 23: ...Kasco Marine Inc 800 Deere Rd Prescott WI 54021 Phone 715 262 4488 Fax 715 262 4487 www kascomarine com sales kascomarine com service kascomarine com 884150...