background image

2

THANKS

We at Kasco Marine, Inc. would like to both thank and 

congratulate you on your purchase of the JF model 

aerating fountain.  We appreciate you choosing Kasco 

and for your purchase.  Your decision to purchase Kas-

co’s JF model Aerating Fountain will not disappoint 

you.  The JF model Aerating Fountain will be a great 

addition to your body of water.  It will help improve 

the water quality by adding much needed oxygen and 

circulation.  It will also enhance the aesthetics of the 

pond or lake with a beautiful fountain pattern.  The 

lighting package (if purchased) will illuminate your 

fountain for beauty at night.  We thank you for choos-

ing Kasco for your fountain needs and want you to be 

completely satisfied with your purchase.

Important Safety

Please read and follow these extremely important 

safety and handling instructions for your Kasco equip-

ment.  Following these instructions will help ensure 

your safety and the quality performance of your equip-

ment.

•  Under NO circumstances should anyone enter the 

water with the electrical equipment plugged in 

and/or in operation.  All Kasco equipment is ETL 

approved to UL and CSA standards for safety in 

water and all fountain models include control pan-

els with GFI protection.  However, it is NEVER 

recommended to enter the water with the equip-

ment in operation.

•  Caution should be used when dealing with any 

electrical equipment with moving parts.

•  NEVER run the unit out of water.  It will damage 

the seals and create a dangerous situation for the 

operator.

•  Extreme caution should be used around water, 

especially cold water, such as in Spring, Fall, and 

Winter, which poses a hazard in and of itself.

•  NEVER lift or drag the fountain by the power or 

light cord.  If you need to pull the unit to the side 

of the pond, use the anchoring ropes.

•  Do not use waders in deep ponds/lakes or ponds/

lakes with drop-offs, drastic slopes, or soft bottom 

material.

•  Do not use boats that tip easily for fountain in-

stallation, such as a canoe, and follow all boating 

safety rules and regulations, including wearing a 

PFD. (Personal Flotation Device)

•  The fountain is supplied with an internal ground-

ing conductor and a grounding-type attachment 

plug.  To reduce the risk of electrical shock, 

be certain that the fountain is plugged into the 

C-25 Control Box (120V) or C-85 Control Panel 

(240/208V) supplied by Kasco and that the C-25 

is plugged into a properly grounded, grounding 

type receptacle or the C-85 is wired properly.  The 

GFCI breakers should be tested upon each instal-

lation and every month thereafter to ensure proper 
operation.

General Instructions

INSPECT THE SHIPMENT

Immediately inspect your Kasco Fountain shipment 

for any visible damages.  Also cross reference the 

parts supplied with the Parts Included sheet to check 

for shortages.  Shortages should be reported immedi-

ately to your Kasco Marine distributor or representa-

tive and damages reported to your carrier and Kasco 

Marine.

CAUTION

WARNING:  Under NO circumstances should anyone 

enter the water with the unit in operation.  Always 

operate the unit in the water and keep people and ob-

jects clear of the propeller.  Do not lift or pull the unit 

by the electrical cord.  Always use extreme caution 

around electrical equipment and water situations.

ASSEMBLY & INSTALLATION

Please see the proper Assembly and Installation In-

structions enclosed in this manual.  Each is specific for 

your model and size of Fountain.  Note:  Use a nylon 

tie to help keep the power cords for the unit and lights 

free of the propeller by tying each cord to either side 

of the float. If you have a light kit, make sure that the 

unit cord is tied to one side of the float and the light 

cord to the other for balance.  Note: It is extremely 

important to test the GFI breaker in the control panel 

upon each installation/reinstallation of the unit to en-

sure proper functioning.

WARRANTY

Kasco Fountains are the result of over 40 years of 

design and engineering.  Kasco products are built to 

withstand the toughest conditions.  Kasco Marine 

Summary of Contents for 3400JF

Page 1: ...l Panel Installation pg11 C 25 Timer Control Instructions pg13 C85 non metallic Wiring Diagram pg14 C85 C95 non metallic Control Panel Timer pg15 Maintenance Recommendations pg16 Warranty Policy pg17...

Page 2: ...not use boats that tip easily for fountain in stallation such as a canoe and follow all boating safety rules and regulations including wearing a PFD Personal Flotation Device The fountain is supplied...

Page 3: ...ady for immediate use after installation The motor and ball bearings are submerged in oil and no further lubrication is needed Make sure to keep the motor housing clean from hard water deposits and or...

Page 4: ...r screw s for mounting the C 25 3 or C 85 4 7 16 Socket and Ratchet 7 16 Wrench 11 32 wrench for 8 fasteners 3400JF 3400HJF Parts Included Item Part Qty 1 3400JF Aerator 1 2 Float 242001 1 3 1 4 20 x...

Page 5: ...bolt holes with legs 2 Lock washer goes between bolt and flat washer Tighten down in 4 places 3 Turn over Bring bottom screen sections together 4 Tighten down in 6 places to hold the screen together...

Page 6: ...one of the pump 7 Thread one rope through one weighted tube rope Weight and position it approximately 6 from the float Next thread the end of the rope back through the opening facing the float as show...

Page 7: ...ond on a post with room for mounting the C 25 or C 85 Two 12 pieces of 1 galvanized pipe or weighted tubing for weighting ropes optional 10 x 1 long or longer screw s for mounting the C 25 3 or C 85 4...

Page 8: ...bolt and flat washer Tighten down in 4 places to the float retaining clips 3 Turn over Bring bottom screen sections together 4 Tighten down in 6 places to hold the screen together For quicker assembl...

Page 9: ...Without Strain Relief 6 Choose Nozzle Fit bolt into the molded socket on the nozzle and thread into the inner cone of the pump 7 If ready to install in the pond go to Installation instructions Light...

Page 10: ...by regional electrical differenc es or voltage drop due to long power cords may result in reduced pattern sizes The Cypress is the only nozzle that uses the sepa rate collar labeled C2 The Cypress Lin...

Page 11: ...ctrician or service person if needed For 120V Installations Plug the aerator cord into the C 25 outlet labeled UNIT If lights are included plug the Transformer cord into the C 25 outlet labeled LIGHT...

Page 12: ...provided with this panel L1 connects to Terminal 1 L2 connects to Terminal 2 N connects to Terminal N G connects to Terminal GROUND located on hassis plate Be sure to provide adequate sized power cond...

Page 13: ...2 If the G F C I tests okay restore power by pushing the RESET button back in THE RESET BUTTON MUST BE PUSHED FIRMLY AND FULLY INTO PLACE UNTIL IT LOCKS AND RE MAINS DEPRESSED AFTER PRES SURE HAS BEE...

Page 14: ...14 C85 non metallic Wiring Diagram...

Page 15: ...r and the minute dial will show exac ly 10 30 PROGRAMMING Dimensions FM 1 synchronous quartz TIME SETTING TO SET THE CURRENT TIME AND DAY OF WEEK ON 7 DAY UNITS TURN THE MINUTE HAND CLOCKWISE DO NOT S...

Page 16: ...ll installations at least every two to three months Seal replacement and all other repair services should be performed by Kasco Marine or a Kasco trained Authorized Repair Center Any alterations or ch...

Page 17: ...r local distributor with the shipment If no Repair Form is available include your name and physical address for return delivery of the repaired unit and a daytime phone number and or e mail ad void th...

Page 18: ...off and back on without the timer and without tripping the GFI breaker Each Kasco Fountain has a Thermal Overload built in that will turn the unit off when it overheats Once the unit has cooled down i...

Page 19: ...ed of water If the unit does not have the proper amount of water the flow or pattern will fluc tuate up and down and look sporadic If you are see ing these symptoms unplug the unit and clean away the...

Page 20: ...5 MAIN HOUSING 2400J 3400J 1 7 241005 V TUBE WITH LEGS 1 8 342050 IMPELLER 3400J 1 9 990275 O RING CORD 1 10 475643 SHAFT WASHER 2 11 243475 ZINC ASSEMBLY 1 12 990280 SEALING PLUG 1 13 990281 O RING 1...

Page 21: ...21 4400J Replacement Parts...

Page 22: ...panel with unit unless otherwise instructed A fee of 60 per hour will be assessed for cleaning excessively dirty units and float disassembly Refer to the Owner s manual for easy to follow troubleshoot...

Page 23: ...23...

Page 24: ...______ Serial Ex 5101J341725 ______________________________ Purchase Date _____________________ Purchased From ___________________________________ Registration Date ___________________________ Kasco M...

Reviews: