Kasco Aeration 3400JF Owner'S Manual Download Page 4

4

Set of 5 Interchangeable Nozzles (5) 
 

1.  3/8” x 2.25” bolt (1)

 

2.  3/8” x 4” bolt (1)

 

3.  Linden Nozzle (1)

 

4.  Sequoia Nozzle (1)

 

5.  Juniper Nozzle (1)

 

6.  Willow Nozzle (1)

 

7.  Cypress Nozzle (1)

 

8.  Collar for Cypress Nozzle (1)

Also Included:

Mesh screen (1) with cable ties (10)

• 

Mooring Rope Pipe Weights (2)

• 

Cord in separate box (1) (depending on size of 

• 

cord)
Control Box (C-25 for 120V units in Float box 

• 

or C-85 for 240V units in separate box) (1) (Not 
Pictured)

TOOLS & SUPPLIES NEEDED

Anchors or stakes for installing unit (2)

• 

# 2 Phillips head screw driver 

• 

120V or 240V Electrical Supply near pond on a 

• 

post with room for mounting the C-25 or C-85 
Two 12” pieces of 1” galvanized pipe or weighted 

• 

tubing for weighting ropes (optional)
#10 x 1” long or longer screw(s) for mounting the 

• 

C-25 (3) or C-85 (4)
9/16” Socket and Ratchet 

• 

9/16” Wrench

• 

3400JF, 3400HJF Assembly

STEP ONE
Make sure you have all the parts needed.  If any short-
ages are found, contact your Kasco representative 
immediately.

3400JF, 3400HJF Parts Included

3400JF Aerating Fountain (Unit with cord or unit 

1. 

with Disconnect) (1)
Float (with two 50’ mooring ropes attached) (1)

2. 

1/4-20 x 3 1/4” Phillips Pan Head Screw (4)

3. 

1/4” split washers  (4)

4. 

1/4” (3/4” outer diameter) Flat Washer (4)

5. 

3/8”-16 x 1-3/4” Hex Head Bolt (2)

6. 

3/8” Flat Washer (4)

7. 

Cushions for Legs (4)

8. 

Bottom Screen cushions (3)

9. 

Bottom Screen (1)

10. 

Bottom Screen Clips (2)

11. 

3/8”-16 Nylon Lock Nut (2)

12. 

1

2

3

4

5

6

7

8

9

10

11

12

• 

Summary of Contents for 3400JF

Page 1: ...ntrol Panel Installation pg11 C 25 Timer Control Instructions pg12 C85 non metallic Wiring Diagram pg14 C85 C95 non metallic and 3 Phase Control Panel Timer pg15 Maintenance Recommendations pg16 Warra...

Page 2: ...not use boats that tip easily for fountain in stallation such as a canoe and follow all boating safety rules and regulations including wearing a PFD Personal Flotation Device The fountain is supplied...

Page 3: ...O around the unit and from below the unit The water is pulled upward and thrust through the flotation collar into the air Your Kasco Marine Fountain is ready for immediate use after installation The m...

Page 4: ...C 25 or C 85 Two 12 pieces of 1 galvanized pipe or weighted tubing for weighting ropes optional 10 x 1 long or longer screw s for mounting the C 25 3 or C 85 4 9 16 Socket and Ratchet 9 16 Wrench 3400...

Page 5: ...end Tighten until snug and repeat with remaining clip STEP EIGHT Turn the assembly upright again At this time if the cord contains a metal strain relief you can use the chain connector and attach it i...

Page 6: ...ain relief on the cord If a Strain Relief is present on the cord you may disregard the Nylon Tie On cords with a Quick Disconnect the discon nect should be tightened properly to avoid leaking If insta...

Page 7: ...then thread into the retaining clip float retain float retaining clip ing clip Tighten until snug with a Phillips Head screw driver and repeat for 3 remaining screws Set of 5 Interchangeable Nozzles 5...

Page 8: ...e cure mesh vertical seam at the top bottom and middle STEP FIVE See Mesh Screen Attachment section before con necting the bottom screen to the float Turn secured assembly upside down so the top of th...

Page 9: ...2 25 bolt To install simply drop the bolt through the nozzle and thread into the top of the cone on the fountain Cypress Display The Cypress nozzle marked C1 on fin makes use of the collar marked C2...

Page 10: ...e the water level fluctuates significantly you may need to suspend a small weight 12 of 1 galvanize pipe works well at the mid point of the rope to take up any slack as the water level drops The weigh...

Page 11: ...d power conductors to prevent excessive voltage drop Consult with your electrician to properly size power feed conductors Use copper conductors only Aerator power cord connection Your aerator pump wil...

Page 12: ...Be sure the timer is in the ON position 2 If the G F C I tests okay restore power by pushing the RESET button back in THE RESET BUTTON MUST BE PUSHED FIRMLY AND FULLY INTO PLACE UNTIL IT should be st...

Page 13: ...ER OPERATION INSTRUCTIONS C 25 Control Box will turn the aerator fountain ON OFF with the TIMER Kasco lights will turn ON with the PHOTO EYE and OFF with TIMER C 25 Control Box is to be used with Kasc...

Page 14: ...14 C85 non metallic Wiring Diagram...

Page 15: ...re pe riod that the aerator is to be turned ON i e fifteen minutes for each tripper on the 24 Hour dial When the tripper is pushed to the inside the switch is in the OFF position PROGRAMMING WITH MANU...

Page 16: ...all installations at least every two to three months Seal replacement and all other repair services should be performed by Kasco Marine or a Kasco trained Authorized Repair Center Any alterations or c...

Page 17: ...r local distributor with the shipment If no Repair Form is available include your name and physical address for return delivery of the repaired unit and a daytime phone number and or e mail ad void th...

Page 18: ...off and back on without the timer and without tripping the GFI breaker Each Kasco Fountain has a Thermal Overload built in that will turn the unit off when it overheats Once the unit has cooled down...

Page 19: ...ed of water If the unit does not have the proper amount of water the flow or pattern will fluc tuate up and down and look sporadic If you are see ing these symptoms unplug the unit and clean away the...

Page 20: ...R 1 4 4 6 251250 14 X 1 1 4 LONG HEX WASHER HEAD 4 7 990281 O RING 1 8 990280 SEALING PLUG 1 9 990400 LIP SEAL 1 10 990275 O RING CORD 1 11 243475 ZINC ASSEMBLY 1 12 342050 IMPELLER 3400J 1 13 334125...

Page 21: ...21 4400J Replacement Parts 4400J Replacement Parts...

Page 22: ...clude the power cord and cage assembly fountain housing with each unit sent in for repair to be considered for warranty and for proper repair and shipping protection Do not ship the float and or contr...

Page 23: ...23...

Page 24: ...rds Model Ex 3400JF _______________________________ Serial Ex 8001J31725 ______________________________ Purchase Date _____________________ Purchased From ___________________________________ Registrat...

Reviews: