Record the following data while the Aerator is
operating in the water under load:
Voltage:
L1-L2 ________
L1-N _________
L2-N _________
Amperage:
L1 __________
L2 __________
Date installed _____/_____/_____
Any unauthorized modifi cations to this control panel
will void the UL listing and the Kasco warranty.
C-25 Timer Control Instructions
Portable Timer with Ground Fault Interrupter
(Unit: 9.8 FLA, 58.8 LRA 120 VAC
Light: 300 W, 120 VAC)
IMPORTANT
This portable timer is designed for CONTROLLING the
connected equipment only. Unplug timer before servic-
ing the unit or the equipment it controls. THE MANUAL
OVERRIDE KNOB IS NOT TO BE USED AS A POWER
DISCONNECT! For maximum protection against electri-
cal shock hazard, perform test procedure on G.F.C.I. at least
once a month. Mount at least 5 ft. from open water.
G.F.C.I. TEST PROCEDURE
The G.F.C.I. should be checked every month to make sure
that it is operating properly. Just follow the simple instruc-
tions below. It is recommended to maintain a maintenance
diary of your monthly safety check.
1. Push TEST button, RESET button should pop out from
inner surface. This should result in power being OFF at
the outlet protected by the G.F.C.I. Verify by plugging a
test lamp into the outlet. Be sure the timer is in the ON
position.
2. If the G.F.C.I. tests okay, restore power by pushing the
RESET button back in. THE RESET BUTTON MUST BE
PUSHED FIRMLY AND FULLY INTO PLACE UNTIL IT
should be stripped back at least 3inches. Follow the
connection diagram for terminating these three wires
to the terminal blocks in the control panel.
Black connects to Terminal #4
White connects to Terminal #5
Green connects to Terminal G
Light Kit connection:
If you purchased a Kasco light kit(s) for your aerator,
follow the light kit installation instructions for
mounting the light kit(s) to the aerator fl oat.
This control panel requires a hardwire connection for
the light kit(s). To connect the light kit(s) you will
need to cut off the power cord plug that is molded to
the light kit power cord. Strip back the black outer
jacket of the light kit power cord at least 3inches
to reveal the three internal wires of the power cord.
(black, white, and green conductors). These three
wires will need to be stripped back 1/2”. Follow the
connection diagram for terminating these three wires
to the terminal blocks in the control panel.
Light kit connections:
Black connects to Terminal #6
White connects to Terminal #7
Green connects to Terminal G
STEP FOUR:
Test the GFCB with the test button now and every
30 days.
If lights are installed, they can now be installed per
Instructions included with the lights.
Once completed, power can be restored to the panel.