Kasco Aeration 3400JF Owner'S Manual Download Page 2

2

THANKS
We at Kasco Marine, Inc. would like to both thank and 
congratulate you on your purchase of the JF model 
aerating fountain.  We appreciate you choosing Kasco 
and for your purchase.  Your decision to purchase Kas-
co’s JF model Aerating Fountain will not disappoint 
you.  The JF model Aerating Fountain will be a great 
addition to your body of water.  It will help improve 
the water quality by adding much needed oxygen and 
circulation.  It will also enhance the aesthetics of the 
pond or lake with a beautiful fountain pattern.  The 
lighting package (if purchased) will illuminate your 
fountain for beauty at night.  We thank you for choos-
ing Kasco for your fountain needs and want you to be 

completely satisfi ed with your purchase.

Important Safety

Please read and follow these extremely important 
safety and handling instructions for your Kasco equip-
ment.  Following these instructions will help ensure 
your safety and the quality performance of your equip-
ment.

Under NO circumstances should anyone enter the 

• 

water with the electrical equipment plugged in 
and/or in operation.  All Kasco equipment is ETL 
approved to UL and CSA standards for safety in 
water and all fountain models include control pan-
els with GFI protection.  However, it is NEVER 
recommended to enter the water with the equip-
ment in operation.
Caution should be used when dealing with any 

• 

electrical equipment with moving parts.
NEVER run the unit out of water.  It will damage 

• 

the seals and create a dangerous situation for the 
operator.
Extreme caution should be used around water, 

• 

especially cold water, such as in Spring, Fall, and 
Winter, which poses a hazard in and of itself.
NEVER lift or drag the fountain by the power or 

• 

light cord.  If you need to pull the unit to the side 
of the pond, use the anchoring ropes.
Do not use waders in deep ponds/lakes or ponds/

• 

lakes with drop-offs, drastic slopes, or soft bottom 
material.
Do not use boats that tip easily for fountain in-

• 

stallation, such as a canoe, and follow all boating 
safety rules and regulations, including wearing a 

PFD. (Personal Flotation Device)
The fountain is supplied with an internal ground-

• 

ing conductor and a grounding-type attachment 
plug.  To reduce the risk of electrical shock, 
be certain that the fountain is plugged into the 
C-25 Control Box (120V) or C-85 Control Panel 
(240/208V) supplied by Kasco and that the C-25 
is plugged into a properly grounded, grounding 
type receptacle or the C-85 is wired properly.  The 
GFCI breakers should be tested upon each instal-
lation and every month thereafter to ensure proper 

operation.

General Instructions

INSPECT THE SHIPMENT
Immediately inspect your Kasco Fountain shipment 
for any visible damages.  Also cross reference the 
parts supplied with the Parts Included sheet to check 
for shortages.  Shortages should be reported immedi-
ately to your Kasco Marine distributor or representa-
tive and damages reported to your carrier and Kasco 
Marine.

CAUTION
WARNING:  Under NO circumstances should anyone 
enter the water with the unit in operation.  Always 
operate the unit in the water and keep people and ob-
jects clear of the propeller.  Do not lift or pull the unit 
by the electrical cord.  Always use extreme caution 
around electrical equipment and water situations.

ASSEMBLY & INSTALLATION
Please see the proper Assembly and Installation In-
structions enclosed in this manual.  Each is specifi c for 
your model and size of Fountain.  Note:  Use a nylon 
tie to help keep the power cords for the unit and lights 
free of the propeller by tying each cord to either side 
of the fl oat. If you have a light kit, make sure that the 
unit cord is tied to one side of the fl oat and the light 
cord to the other for balance.  Note: It is extremely 
important to test the GFI breaker in the control panel 
upon each installation/reinstallation of the unit to en-
sure proper functioning.

WARRANTY
Kasco Fountains are the result of over 40 years of 
design and engineering.  Kasco products are built to 
withstand the toughest conditions.  Kasco Marine 

Summary of Contents for 3400JF

Page 1: ...ntrol Panel Installation pg11 C 25 Timer Control Instructions pg12 C85 non metallic Wiring Diagram pg14 C85 C95 non metallic and 3 Phase Control Panel Timer pg15 Maintenance Recommendations pg16 Warra...

Page 2: ...not use boats that tip easily for fountain in stallation such as a canoe and follow all boating safety rules and regulations including wearing a PFD Personal Flotation Device The fountain is supplied...

Page 3: ...O around the unit and from below the unit The water is pulled upward and thrust through the flotation collar into the air Your Kasco Marine Fountain is ready for immediate use after installation The m...

Page 4: ...C 25 or C 85 Two 12 pieces of 1 galvanized pipe or weighted tubing for weighting ropes optional 10 x 1 long or longer screw s for mounting the C 25 3 or C 85 4 9 16 Socket and Ratchet 9 16 Wrench 3400...

Page 5: ...end Tighten until snug and repeat with remaining clip STEP EIGHT Turn the assembly upright again At this time if the cord contains a metal strain relief you can use the chain connector and attach it i...

Page 6: ...ain relief on the cord If a Strain Relief is present on the cord you may disregard the Nylon Tie On cords with a Quick Disconnect the discon nect should be tightened properly to avoid leaking If insta...

Page 7: ...then thread into the retaining clip float retain float retaining clip ing clip Tighten until snug with a Phillips Head screw driver and repeat for 3 remaining screws Set of 5 Interchangeable Nozzles 5...

Page 8: ...e cure mesh vertical seam at the top bottom and middle STEP FIVE See Mesh Screen Attachment section before con necting the bottom screen to the float Turn secured assembly upside down so the top of th...

Page 9: ...2 25 bolt To install simply drop the bolt through the nozzle and thread into the top of the cone on the fountain Cypress Display The Cypress nozzle marked C1 on fin makes use of the collar marked C2...

Page 10: ...e the water level fluctuates significantly you may need to suspend a small weight 12 of 1 galvanize pipe works well at the mid point of the rope to take up any slack as the water level drops The weigh...

Page 11: ...d power conductors to prevent excessive voltage drop Consult with your electrician to properly size power feed conductors Use copper conductors only Aerator power cord connection Your aerator pump wil...

Page 12: ...Be sure the timer is in the ON position 2 If the G F C I tests okay restore power by pushing the RESET button back in THE RESET BUTTON MUST BE PUSHED FIRMLY AND FULLY INTO PLACE UNTIL IT should be st...

Page 13: ...ER OPERATION INSTRUCTIONS C 25 Control Box will turn the aerator fountain ON OFF with the TIMER Kasco lights will turn ON with the PHOTO EYE and OFF with TIMER C 25 Control Box is to be used with Kasc...

Page 14: ...14 C85 non metallic Wiring Diagram...

Page 15: ...re pe riod that the aerator is to be turned ON i e fifteen minutes for each tripper on the 24 Hour dial When the tripper is pushed to the inside the switch is in the OFF position PROGRAMMING WITH MANU...

Page 16: ...all installations at least every two to three months Seal replacement and all other repair services should be performed by Kasco Marine or a Kasco trained Authorized Repair Center Any alterations or c...

Page 17: ...r local distributor with the shipment If no Repair Form is available include your name and physical address for return delivery of the repaired unit and a daytime phone number and or e mail ad void th...

Page 18: ...off and back on without the timer and without tripping the GFI breaker Each Kasco Fountain has a Thermal Overload built in that will turn the unit off when it overheats Once the unit has cooled down...

Page 19: ...ed of water If the unit does not have the proper amount of water the flow or pattern will fluc tuate up and down and look sporadic If you are see ing these symptoms unplug the unit and clean away the...

Page 20: ...R 1 4 4 6 251250 14 X 1 1 4 LONG HEX WASHER HEAD 4 7 990281 O RING 1 8 990280 SEALING PLUG 1 9 990400 LIP SEAL 1 10 990275 O RING CORD 1 11 243475 ZINC ASSEMBLY 1 12 342050 IMPELLER 3400J 1 13 334125...

Page 21: ...21 4400J Replacement Parts 4400J Replacement Parts...

Page 22: ...clude the power cord and cage assembly fountain housing with each unit sent in for repair to be considered for warranty and for proper repair and shipping protection Do not ship the float and or contr...

Page 23: ...23...

Page 24: ...rds Model Ex 3400JF _______________________________ Serial Ex 8001J31725 ______________________________ Purchase Date _____________________ Purchased From ___________________________________ Registrat...

Reviews: