Kasco Aeration 3400JF Owner'S Manual Download Page 1

Owners Manual

Aerating Fountains

3400JF & 3400HJF

4400JF & 4400HJF

Contents

Important Safety. . . . 

pg2

General Instructions. . . . 

pg2

Cord Gauge Chart. . . . 

pg3

Unit Specs. . . . 

pg3

3400JF, 3400HJF Parts Included. . . . 

pg4

3400JF, 3400HJF Assembly. . . . 

pg4

4400JF, 4400HJF Parts Included. . . . 

pg6

4400JF, 4400HJF Assembly. . . . 

pg7

Mesh Screen Attachment. . . . 

pg8

Nozzle Options. . . . 

pg9

Installation Instructions. . . . 

pg10

Control Panel Installation. . . . 

pg11

C-25 Timer Control Instructions. . . . 

pg12

C85 non-metallic Wiring Diagram. . . . 

pg14

C85 / C95 non-metallic and 3 Phase Control Panel Timer. . . . 

pg15

Maintenance Recommendations. . . . 

pg16

Warranty Policy. . . . 

pg17

Troubleshooting Tips. . . . 

pg18

3400J Replacement Parts. . . . 

pg20

4400J Replacement Parts. . . . 

pg21

Customer Repair Form. . . . 

pg22

Registration Information. . . . 

pg24

 Rev. 05/22/12

Kasco Marine, Inc.

800 Deere Rd.

Prescott, WI 54021

PH (715) 262-4488  

FAX (715) 262-4487

www.kascomarine.com

C

Intertek

3020379

ANSI/UL 778, 5th Ed. 2010

CAN/CSA C22.2 No. 108-M89

UL 50, 11th Ed. 1995

Summary of Contents for 3400JF

Page 1: ...ntrol Panel Installation pg11 C 25 Timer Control Instructions pg12 C85 non metallic Wiring Diagram pg14 C85 C95 non metallic and 3 Phase Control Panel Timer pg15 Maintenance Recommendations pg16 Warra...

Page 2: ...not use boats that tip easily for fountain in stallation such as a canoe and follow all boating safety rules and regulations including wearing a PFD Personal Flotation Device The fountain is supplied...

Page 3: ...O around the unit and from below the unit The water is pulled upward and thrust through the flotation collar into the air Your Kasco Marine Fountain is ready for immediate use after installation The m...

Page 4: ...C 25 or C 85 Two 12 pieces of 1 galvanized pipe or weighted tubing for weighting ropes optional 10 x 1 long or longer screw s for mounting the C 25 3 or C 85 4 9 16 Socket and Ratchet 9 16 Wrench 3400...

Page 5: ...end Tighten until snug and repeat with remaining clip STEP EIGHT Turn the assembly upright again At this time if the cord contains a metal strain relief you can use the chain connector and attach it i...

Page 6: ...ain relief on the cord If a Strain Relief is present on the cord you may disregard the Nylon Tie On cords with a Quick Disconnect the discon nect should be tightened properly to avoid leaking If insta...

Page 7: ...then thread into the retaining clip float retain float retaining clip ing clip Tighten until snug with a Phillips Head screw driver and repeat for 3 remaining screws Set of 5 Interchangeable Nozzles 5...

Page 8: ...e cure mesh vertical seam at the top bottom and middle STEP FIVE See Mesh Screen Attachment section before con necting the bottom screen to the float Turn secured assembly upside down so the top of th...

Page 9: ...2 25 bolt To install simply drop the bolt through the nozzle and thread into the top of the cone on the fountain Cypress Display The Cypress nozzle marked C1 on fin makes use of the collar marked C2...

Page 10: ...e the water level fluctuates significantly you may need to suspend a small weight 12 of 1 galvanize pipe works well at the mid point of the rope to take up any slack as the water level drops The weigh...

Page 11: ...d power conductors to prevent excessive voltage drop Consult with your electrician to properly size power feed conductors Use copper conductors only Aerator power cord connection Your aerator pump wil...

Page 12: ...Be sure the timer is in the ON position 2 If the G F C I tests okay restore power by pushing the RESET button back in THE RESET BUTTON MUST BE PUSHED FIRMLY AND FULLY INTO PLACE UNTIL IT should be st...

Page 13: ...ER OPERATION INSTRUCTIONS C 25 Control Box will turn the aerator fountain ON OFF with the TIMER Kasco lights will turn ON with the PHOTO EYE and OFF with TIMER C 25 Control Box is to be used with Kasc...

Page 14: ...14 C85 non metallic Wiring Diagram...

Page 15: ...re pe riod that the aerator is to be turned ON i e fifteen minutes for each tripper on the 24 Hour dial When the tripper is pushed to the inside the switch is in the OFF position PROGRAMMING WITH MANU...

Page 16: ...all installations at least every two to three months Seal replacement and all other repair services should be performed by Kasco Marine or a Kasco trained Authorized Repair Center Any alterations or c...

Page 17: ...r local distributor with the shipment If no Repair Form is available include your name and physical address for return delivery of the repaired unit and a daytime phone number and or e mail ad void th...

Page 18: ...off and back on without the timer and without tripping the GFI breaker Each Kasco Fountain has a Thermal Overload built in that will turn the unit off when it overheats Once the unit has cooled down...

Page 19: ...ed of water If the unit does not have the proper amount of water the flow or pattern will fluc tuate up and down and look sporadic If you are see ing these symptoms unplug the unit and clean away the...

Page 20: ...R 1 4 4 6 251250 14 X 1 1 4 LONG HEX WASHER HEAD 4 7 990281 O RING 1 8 990280 SEALING PLUG 1 9 990400 LIP SEAL 1 10 990275 O RING CORD 1 11 243475 ZINC ASSEMBLY 1 12 342050 IMPELLER 3400J 1 13 334125...

Page 21: ...21 4400J Replacement Parts 4400J Replacement Parts...

Page 22: ...clude the power cord and cage assembly fountain housing with each unit sent in for repair to be considered for warranty and for proper repair and shipping protection Do not ship the float and or contr...

Page 23: ...23...

Page 24: ...rds Model Ex 3400JF _______________________________ Serial Ex 8001J31725 ______________________________ Purchase Date _____________________ Purchased From ___________________________________ Registrat...

Reviews: