Kasco Aeration 3400HJF Owner'S Manual Download Page 2

2

THANKS
We at Kasco Marine, Inc. would like to both thank and 
congratulate you on your purchase of the JF model 
aerating fountain.  We appreciate you choosing Kasco 
and for your purchase.  Your decision to purchase Kas-
co’s JF model Aerating Fountain will not disappoint 
you.  The JF model Aerating Fountain will be a great 
addition to your body of water.  It will help improve 
the water quality by adding much needed oxygen and 
circulation.  It will also enhance the aesthetics of the 
pond or lake with a beautiful fountain pattern.  The 
lighting package (if purchased) will illuminate your 
fountain for beauty at night.  We thank you for choos-
ing Kasco for your fountain needs and want you to be 

completely satisfi ed with your purchase.

Important Safety

Please read and follow these extremely important 
safety and handling instructions for your Kasco equip-
ment.  Following these instructions will help ensure 
your safety and the quality performance of your equip-
ment.

Under NO circumstances should anyone enter the 

• 

water with the electrical equipment plugged in 
and/or in operation.  All Kasco equipment is ETL 
approved to UL and CSA standards for safety in 
water and all fountain models include control pan-
els with GFI protection.  However, it is NEVER 
recommended to enter the water with the equip-
ment in operation.
Caution should be used when dealing with any 

• 

electrical equipment with moving parts.
NEVER run the unit out of water.  It will damage 

• 

the seals and create a dangerous situation for the 
operator.
Extreme caution should be used around water, 

• 

especially cold water, such as in Spring, Fall, and 
Winter, which poses a hazard in and of itself.
NEVER lift or drag the fountain by the power or 

• 

light cord.  If you need to pull the unit to the side 
of the pond, use the anchoring ropes.
Do not use waders in deep ponds/lakes or ponds/

• 

lakes with drop-offs, drastic slopes, or soft bottom 
material.
Do not use boats that tip easily for fountain in-

• 

stallation, such as a canoe, and follow all boating 
safety rules and regulations, including wearing a 

PFD. (Personal Flotation Device)
The fountain is supplied with an internal ground-

• 

ing conductor and a grounding-type attachment 
plug.  To reduce the risk of electrical shock, 
be certain that the fountain is plugged into the 
C-25 Control Box (120V) or C-85 Control Panel 
(240/208V) supplied by Kasco and that the C-25 
is plugged into a properly grounded, grounding 
type receptacle or the C-85 is wired properly.  The 
GFCI breakers should be tested upon each instal-
lation and every month thereafter to ensure proper 

operation.

General Instructions

INSPECT THE SHIPMENT
Immediately inspect your Kasco Fountain shipment 
for any visible damages.  Also cross reference the 
parts supplied with the Parts Included sheet to check 
for shortages.  Shortages should be reported immedi-
ately to your Kasco Marine distributor or representa-
tive and damages reported to your carrier and Kasco 
Marine.

CAUTION
WARNING:  Under NO circumstances should anyone 
enter the water with the unit in operation.  Always 
operate the unit in the water and keep people and ob-
jects clear of the propeller.  Do not lift or pull the unit 
by the electrical cord.  Always use extreme caution 
around electrical equipment and water situations.

ASSEMBLY & INSTALLATION
Please see the proper Assembly and Installation In-
structions enclosed in this manual.  Each is specifi c for 
your model and size of Fountain.  Note:  Use a nylon 
tie to help keep the power cords for the unit and lights 
free of the propeller by tying each cord to either side 
of the fl oat. If you have a light kit, make sure that the 
unit cord is tied to one side of the fl oat and the light 
cord to the other for balance.  Note: It is extremely 
important to test the GFI breaker in the control panel 
upon each installation/reinstallation of the unit to en-
sure proper functioning.

WARRANTY
Kasco Fountains are the result of over 40 years of 
design and engineering.  Kasco products are built to 
withstand the toughest conditions.  Kasco Marine 

Summary of Contents for 3400HJF

Page 1: ...ontrol Panel Installation pg11 C 25 Timer Control Instructions pg12 C85 non metallic Wiring Diagram pg14 C85 C95 non metallic and 3 Phase Control Panel Timer pg15 Maintenance Recommendations pg16 Warranty Policy pg17 Troubleshooting Tips pg18 3400J Replacement Parts pg20 4400J Replacement Parts pg21 Customer Repair Form pg22 Registration Information pg24 Rev 05 22 12 Kasco Marine Inc 800 Deere Rd ...

Page 2: ... not use boats that tip easily for fountain in stallation such as a canoe and follow all boating safety rules and regulations including wearing a PFD Personal Flotation Device The fountain is supplied with an internal ground ing conductor and a grounding type attachment plug To reduce the risk of electrical shock be certain that the fountain is plugged into the C 25 Control Box 120V or C 85 Contro...

Page 3: ... O around the unit and from below the unit The water is pulled upward and thrust through the flotation collar into the air Your Kasco Marine Fountain is ready for immediate use after installation The motor and ball bearings are submerged in oil and no further lubrication is needed Make sure to keep the motor housing clean from hard water deposits and or algae See Mainte nance Recommendations It is...

Page 4: ... C 25 or C 85 Two 12 pieces of 1 galvanized pipe or weighted tubing for weighting ropes optional 10 x 1 long or longer screw s for mounting the C 25 3 or C 85 4 9 16 Socket and Ratchet 9 16 Wrench 3400JF 3400HJF Assembly STEP ONE Make sure you have all the parts needed If any short ages are found contact your Kasco representative immediately 3400JF 3400HJF Parts Included 3400JF Aerating Fountain U...

Page 5: ... end Tighten until snug and repeat with remaining clip STEP EIGHT Turn the assembly upright again At this time if the cord contains a metal strain relief you can use the chain connector and attach it in one of the opening at the rope placement The chain connector will easily fit STEP TWO Set motor housing upright stainless steel can down on a flat surface STEP THREE Peel off the adhesive on one of...

Page 6: ...rain relief on the cord If a Strain Relief is present on the cord you may disregard the Nylon Tie On cords with a Quick Disconnect the discon nect should be tightened properly to avoid leaking If installing a new Quick Disconnect refer to Quick Disconnect Instructions STEP NINE Select a nozzle See JF Nozzle Options Insert the Shaft Bolt into the Nozzle Head so it fits snugly into the molded socket...

Page 7: ... then thread into the retaining clip float retain float retaining clip ing clip Tighten until snug with a Phillips Head screw driver and repeat for 3 remaining screws Set of 5 Interchangeable Nozzles 5 1 3 8 x 2 25 bolt 1 2 3 8 x 4 bolt 1 3 Linden Nozzle 1 4 Sequoia Nozzle 1 5 Juniper Nozzle 1 6 Willow Nozzle 1 7 Cypress Nozzle 1 8 Collar for Cypress Nozzle 1 Also Included Mesh screen 1 with cable...

Page 8: ...Se cure mesh vertical seam at the top bottom and middle STEP FIVE See Mesh Screen Attachment section before con necting the bottom screen to the float Turn secured assembly upside down so the top of the float logo side is face down on the flat surface Place Bottom Screen Part 10 onto the bottom side of the float Make sure the wide opening of the screen is against the float and the 3 handles on the...

Page 9: ...x 2 25 bolt To install simply drop the bolt through the nozzle and thread into the top of the cone on the fountain Cypress Display The Cypress nozzle marked C1 on fin makes use of the collar marked C2 on the top rim and the 3 8 x 4 bolt Model Height Width 3400JF HJF 6 16 4400JF HJF 7 5 25 using 3 cable ties Overlap vertical edges 1 inch overlap Attach 3 cable ties 2 Insert existing stainless steel...

Page 10: ...re the water level fluctuates significantly you may need to suspend a small weight 12 of 1 galvanize pipe works well at the mid point of the rope to take up any slack as the water level drops The weight should be light enough so the Fountain can rise as the water level rises This can also help hide ropes by sinking them further below the surface Linden Display The Linden nozzle marked L inside one...

Page 11: ...ed power conductors to prevent excessive voltage drop Consult with your electrician to properly size power feed conductors Use copper conductors only Aerator power cord connection Your aerator pump will be provided with a flexible power cord for connection to this control panel If the power cord has a plug you will need to cut it off The power cord conductors black white green will need to be stri...

Page 12: ...t Be sure the timer is in the ON position 2 If the G F C I tests okay restore power by pushing the RESET button back in THE RESET BUTTON MUST BE PUSHED FIRMLY AND FULLY INTO PLACE UNTIL IT should be stripped back at least 3inches Follow the connection diagram for terminating these three wires to the terminal blocks in the control panel Black connects to Terminal 4 White connects to Terminal 5 Gree...

Page 13: ...MER OPERATION INSTRUCTIONS C 25 Control Box will turn the aerator fountain ON OFF with the TIMER Kasco lights will turn ON with the PHOTO EYE and OFF with TIMER C 25 Control Box is to be used with Kasco Approved Lights ONLY Insert ON GREEN and OFF RED trippers into dial at desired ON and OFF times Turn dial clockwise one or more revolutions until correct time of day AM or PM in window is aligned w...

Page 14: ...14 C85 non metallic Wiring Diagram ...

Page 15: ...ire pe riod that the aerator is to be turned ON i e fifteen minutes for each tripper on the 24 Hour dial When the tripper is pushed to the inside the switch is in the OFF position PROGRAMMING WITH MANUAL OVERRIDE SWITCH Your Timer may have a 3 way manual switch or a 2 way manual switch AUTOMATIC MODE In order to operate the time clock in the automatic mode the manual switch must be in the automati...

Page 16: ... all installations at least every two to three months Seal replacement and all other repair services should be performed by Kasco Marine or a Kasco trained Authorized Repair Center Any alterations or changes made to Kasco units by an unauthorized source will Maintenance Recommendations Under No Circumstances should anyone enter the water while a fountain is operating Please keep the original box f...

Page 17: ...ur local distributor with the shipment If no Repair Form is available include your name and physical address for return delivery of the repaired unit and a daytime phone number and or e mail ad void the warranty This includes tampering with the unit power cord and or control box Please contact Kasco Marine Inc at 715 262 4488 for your nearest Authorized Repair Center Warranty Policy Warranty Perio...

Page 18: ...f off and back on without the timer and without tripping the GFI breaker Each Kasco Fountain has a Thermal Overload built in that will turn the unit off when it overheats Once the unit has cooled down it will start back up If dress for correspondence regarding the warranty claim Any expedited shipping method for the return of the unit is at the customer s expense Kasco Marine will return units rep...

Page 19: ...ved of water If the unit does not have the proper amount of water the flow or pattern will fluc tuate up and down and look sporadic If you are see ing these symptoms unplug the unit and clean away the debris that is clogging up the screen Another possibility if these symptoms are noticed is a chipped or damaged prop that is causing the unit to wobble and not pump properly When the unit is unplugge...

Page 20: ...ER 1 4 4 6 251250 14 X 1 1 4 LONG HEX WASHER HEAD 4 7 990281 O RING 1 8 990280 SEALING PLUG 1 9 990400 LIP SEAL 1 10 990275 O RING CORD 1 11 243475 ZINC ASSEMBLY 1 12 342050 IMPELLER 3400J 1 13 334125 MAIN HOUSING 2400J 3400J 1 14 344100 INNER HOUSING 2400J 3400J 1 15 334150 CONE 2400J 3400J 1 16 334175 INNER CHAMBER 2400J 3400J 1 17 334306 6 X 3 4 LONG PHILLIPS HEAD SS 10 18 334300 6 WASHER 4 340...

Page 21: ...21 4400J Replacement Parts 4400J Replacement Parts ...

Page 22: ...nclude the power cord and cage assembly fountain housing with each unit sent in for repair to be considered for warranty and for proper repair and shipping protection Do not ship the float and or control box with the unit for repair unless otherwise instructed Today s Date ___________________ Customer Information Name _________________ Phone Number _____________________ Address ___________________...

Page 23: ...23 ...

Page 24: ...ords Model Ex 3400JF _______________________________ Serial Ex 8001J31725 ______________________________ Purchase Date _____________________ Purchased From ___________________________________ Registration Date ___________________________ Kasco Marine Inc 800 Deere Rd Prescott WI 54021 Phone 715 262 4488 Fax 715 262 4487 www kascomarine com sales kascomarine com 884180 ...

Reviews: