13
LOCKS AND RE-MAINS DEPRESSED AFTER PRES-
SURE HAS BEEN REMOVED.
DANGER: IF RESET BUTTON DOES NOT POP OUT,
IF TEST LAMP REMAINS LIT WHEN RESET BUTTON
DOES POP OUT, OR IF THE G.F.C.I. FAILS TO RE-
SET PROPERLY, DO NOT USE TIMER! CONTACT A
QUALIFIED SERVICE TECHNICIAN!
Failure to use the C-25 with Kasco Fountains will void the
warranty and cause the Fountain to not be listed to UL and
CSA standards via ETL.
UNDER NO CIRCUMSTANCES SHOULD ANYONE
ENTER THE WATER WHEN A UNIT IS IN OPERA-
TION!
TIMER-OPERATION INSTRUCTIONS
C-25 Control Box will turn the aerator/fountain ON &
OFF with the TIMER. Kasco lights will turn ON with the
PHOTO EYE and OFF with TIMER. C-25 Control Box is
to be used with Kasco Approved Lights ONLY!
Insert “ON” (GREEN) and “OFF” (RED) trippers into
•
dial at desired ON and OFF times.
Turn dial clockwise one or more revolutions until
•
correct time-of-day (AM or PM) in window is aligned
with the arrow.
Plug aerator/fountain cord into the RIGHT hand outlet
•
(labeled UNIT).
Plug transformer light cord into LEFT hand outlet
•
(labeled LIGHT).
FOR TEMPORARY MANUAL OPERATION
Rotate MANUAL knob counter-clockwise to desired ON or
OFF position. Timer will follow next automatic operation.
Summary of Contents for 3400HJF
Page 14: ...14 C85 non metallic Wiring Diagram ...
Page 21: ...21 4400J Replacement Parts 4400J Replacement Parts ...
Page 23: ...23 ...