15
C85 / C95 non-metallic and 3
Phase Control Panel Timer
TIME CLOCK SETTING
To set the current time, turn the inner dial clockwise.
Do not set the time by rotating “outer” dial.
Turn the minute hand or small plastic inner dial clock-
wise until the time of day on the outer dial is aligned
with the triangle marker on the inner dial (two o’clock
position).
Example for 10:00 AM. Turn the minute hand clock-
wise until 10:00 AM is aligned with the triangle on
the inner dial. The hour and the minute dial will show
exactly 10:00.
Triangle marker
Captive trippers
(in the on position)
PROGRAMMING
The 24-Hour dial has quarter-hour divisions and AM/
PM indications.
The time switch is programmed by pushing the captive
trippers to the outer ring position for the entire pe-
riod that the aerator is to be turned “ON”, i.e., fi fteen
minutes for each tripper on the 24-Hour dial. When
the tripper is pushed to the inside, the switch is in the
“OFF” position.
PROGRAMMING WITH MANUAL OVERRIDE
SWITCH
Your Timer may have a 3-way manual switch or a
2-way manual switch.
AUTOMATIC MODE
In order to operate the time clock in the automatic
mode, the manual switch must be in the automatic
postion- see diagram.
MANUAL MODE
For the 3-way switch, with the manual override switch
in the lower position, marked “O”, the time clock
output will remain Permanently OFF. In the upper
position, marked “I”, the time clock output will remain
permanently ON.
For the 2-way switch, with the manual override switch
in the lower position, marked “ON” the time clock
output will remain permanently ON.
Override Mode
3-way manual
override switch
I = permanent ON
= automatic
0 = permanent OFF
ON
AUTO
Overide Mode
2-way manual
ON - Permanently ON
overide switch
AUTO - automatic