EN 99
(P) T
HE
12 V
SOCKET IS NOT WORKING
.
→
The control panel is not activated.
→
The living room battery B2 is discharged. (See “Charging the living room battery B2”.)
→
The fuse for the 12 V socket (F9) has blown. (The cause has to be determined.*)
(P) T
HE ELECTRIC STEP IS NOT WORKING
.
→
The living room battery B2 is discharged. (See “Charging the living room battery B2”.)
→
The fuse for the electric step (F4) has blown. (The cause has to be determined.*)
→
The step is defective.*
Heating
(P) T
HE HEATING IS NOT WORKING
.
→
The “heating” circuit breaker interrupts the current flow and has to be deactivated.
→
The heating control panel (Truma CP plus) is not switched on.
→
The fuel tank of the vehicle is empty.
→
The 230 V power supply is not established. (See “Establishing the 230 V power supply”.)
→
The selected temperature is lower than the actual room temperature.
→
The intake opening for circulating air inside the vehicle is blocked.
→
The air intake/outlet element on the outside of the vehicle is blocked.
→
The window with the contactor on the window pane (if fitted) is not closed properly.
→
The fuse for the heating (slot 1) has blown. (The cause has to be determined.*)
Toilet
(P) T
HE TOILET SLIDE VALVE IS NOT WORKING
.
→
The cassette is full.
→
The cassette is not correctly engaged.
(P) T
HE TOILET CASSETTE CANNOT BE PULLED OUT OR PUSHED IN
.
→
The toilet slide valve is open or partially open.
(P) T
HE TOILET CANNOT BE FLUSHED
.
→
The fresh water tank is empty.
→
The fresh water pump is in no-load operation because there is air in the system.
→
The cassette is not correctly engaged.
→
The fuse for the toilet (F9) has blown. (The cause has to be determined.*)
Kitchen
(P) T
HE REFRIGERATOR IS NOT WORKING
.
→
The refrigerator is switched off.
→
The living room battery B2 is discharged. (See “Charging the living room battery B2”.)
→
The fuse for the refrigerator (slot 2) has blown. (The cause has to be determined.*)
(P) T
HE HOB IS NOT WORKING
.
→
The safety valve on the gas cylinder (gas cylinder compartment) is closed.
→
The gas cylinder is empty.
(P) H
IGH GAS CONSUMPTION
/
GAS ODOUR
→
The gas system has a leak.*
Summary of Contents for DEXTER 540
Page 1: ...DEXTER 540 BEDIENUNGSANLEITUNG OPERATING MANUAL ...
Page 3: ...DE 3 Allgemeines ...
Page 10: ...DE 11 Verantwortung des Halters ...
Page 13: ...DE 15 Sicherheit und Brandschutz ...
Page 16: ...DE 19 Beförderung von Personen ...
Page 19: ...DE 23 Frischwasser anlage ...
Page 27: ...DE 33 Gasanlage ...
Page 32: ...DE 39 Elektrische Anlage ...
Page 40: ...DE 49 Heizung ...
Page 44: ...DE 55 WC Anlage ...
Page 51: ...DE 63 Küche ...
Page 55: ...DE 69 Fenster und Dach hauben ...
Page 61: ...DE 77 Wohnen ...
Page 69: ...DE 87 Stilllegung über den Winter ...
Page 72: ...DE 91 Reinigung und Pflege ...
Page 76: ...DE 97 Störungssuche ...
Page 81: ...DE 103 Wartung und Wartungsintervalle ...
Page 86: ...EN 3 General information ...
Page 93: ...EN 11 Owner s responsibility ...
Page 96: ...EN 15 Safety and fire protection ...
Page 99: ...EN 19 Transporting passengers ...
Page 102: ...EN 23 Fresh water system ...
Page 110: ...EN 33 Gas system ...
Page 115: ...EN 39 Electrical system ...
Page 123: ...EN 49 Heating ...
Page 127: ...EN 55 Toilet system ...
Page 134: ...EN 63 Kitchen ...
Page 138: ...EN 69 Windows and roof lights ...
Page 144: ...EN 77 Living ...
Page 152: ...EN 87 Laying up for winter ...
Page 155: ...EN 91 Cleaning and maintenance ...
Page 159: ...EN 97 Troubleshooting ...
Page 164: ...EN 103 Maintenance and maintenance intervals ...