Chapter 3 Operation Panel
31
Code
Parameter
Function
Explanation
Parameter Value
Factory
Setting
Pr.145
Power
frequency
running time
d000.1- -d900.0s
d060.0
Pr.147
Frequency
conversion
d0000:work in frequency conversion only
d0001:with power frequency
d0000
Pr.148
Pr.149
Pr.150
Pr.151
Pr.152
Pr.153
AUTO PLC
d0000: internal PLC invalid
d0001:program operation stop after 1 week
d0002:cycle operation
d0003:Auto operation stop after 1 week
d0004:Auto and cycle operation
d0000
Pr.153
PLC
direction(inter
nal 10 speed
modes,0
refers
FWD
1refers REV
first speed is
the
lowest
level
,
1000000000
refers the 10
th
speed
is
REV
,other
speed is FWD
d0000- -d1023
d0000
Summary of Contents for KD4000 Series
Page 5: ...Chapter 2 Installation and wiring 4 2 2 KD4000 4T 380V Series Installation Dimension...
Page 6: ...Chapter 2 Installation and wiring 5 2 3 KD4000 2S 220V basic wiring diagram...
Page 7: ...Chapter 2 Installation and wiring 6 2 4 SD4000 4T 380V basic wiring diagram...
Page 15: ...Chapter 3 Operation Panel 14 3 3 Please observe below steps to set parameters...