Chapter 3 Operation Panel
18
Code
Parameter
Function
Explanation
Parameter Value
Factory
Setting
Pr.020
Setting
for
percentage of
DC
braking
current
Please
set
0%
when
don’t
need
DC current to
brake
d000.0—d050.0
%
d008.0
Pr.021
Setting
the
time for DC
current
braking
on
start the motor
Set up to 0 to
shut
down
this function
d000.0—d025.0s
d0000
Pr.022
Setting
the
time for DC
current
braking
on
stop the motor
Set up to
0.0s to shut
down
this
function
d000.0—d120.0s
d001.5
Pr.023
Setting
the
starting
frequency for
the
DC
current
braking when
shut
down
motor
Before
decelerating
to stop, this
parameter is
the
starting
frequency for
DC
current
brake. It will
work
when
the
parameter is
smaller than
the
min.
frequency(pr.
008)
d000.0—d060.0 Hz
d001.0
Pr.024
Momentary
power
loss protection
d0000: Operation stops after momentary
power
Loss.
d0000
d0001:
Operation
continues
after
momentary
power loss. Track down with operating
frequency