9
1 Fuse of motor filament filter
2 Fuse of motor multi-channel valve
Check fuses / replace defective fuse.
Note
The equipment may only be installed by
–
KÄRCHER service engineers
–
persons authorized by KÄRCHER
The following requirements are necessary
in order to install the equipment:
–
frost-free room with adequate ventila-
tion and exhausts
–
Floor path for collecting sludge
–
Water and electrical connection: see
"Technical data"
–
horizontal, even foundation
–
Protect the plant against direct sunlight and
spray water
–
Sufficiently illuminate the installation site
–
The floor must be freely accessible.
Unpack the plant and sent the packaging
materials for recycling.
The water installation depends on the spe-
cific conditions of the existing plant compo-
nents such as
–
Type and model of washing unit
–
Type and models of building-side com-
ponents (sludge collector, pump basin,
etc.)
–
Nominal widtht, lengths and type of
channels
Max. permissible supply flow 3,000 l/h at
2.0 bar. If this value is exceeded, throttle
using the attachment kit input valve (4.640-
230.0).
Hence, the water installation must be car-
ried out according to the specific project
documents.
Danger
Risk of injury on account of tripping and falling.
Lay the hoses of the plant in such a way
that they do not pose a risk for tripping and
falling.
Danger
Risk of electrical voltage. All electrical in-
stallations may only be done by an electri-
cian according to the local regulations.
The plant must be secured through a wrong
current protection switch with a triggering
current lesser than or equal to 30 mA.
–
The appliance may only be connected
to alternating current.
–
The appliance may only be connected
to an electrical supply which has been
installed by an electrician in accord-
ance with IEC 60364.
–
The voltage indicated on the type plate
must correspond to the voltage of the
electrical source.
–
The appliance should always be con-
nected to the electrical mains using a
plug. It is forbidden to permanently con-
nect the appliance to the power supply.
The plug is only for mains separation.
We hereby declare that the machine de-
scribed below complies with the relevant
basic safety and health requirements of the
EU Directives, both in its basic design and
construction as well as in the version put
into circulation by us. This declaration shall
cease to be valid if the machine is modified
without our prior approval.
The undersigned act on behalf and under
the power of attorney of the company man-
agement.
Authorised Documentation Representative
S. Reiser
Alfred Kärcher GmbH Co. KG
Alfred-Kärcher-Str. 28 - 40
71364 Winnenden (Germany)
Phone: +49 7195 14-0
Fax: +49 7195 14-2212
Winnenden, 2011/07/01
Fuses
Accessories
Accessories
Order number
Filter inlay
5.033-239.0
Recycled water tank
2.641-981.0
Additional tank
2.642-117.0
Ventilation
2.641-510.0
Overflow
2.641-995.0
Immersion pump
2.642-126.0
Conductivity measure-
ment
2.641-996.0
Add fresh water
2.642-113.0
Circulation pump
2.642-352.0
Input valve
4.640-230.0
Support leg
2.641-849.0
Installing the unit
(only for experts)
Preparing the installation place
Unpack the equipment
Water installation
Electrical connection
EC Declaration of Conformity
Product:
Water treatment plant
Type:
1.217-xxx
Relevant EU Directives
2006/42/EC (+2009/127/EC)
2006/95/EC
2004/108/EC
Applied harmonized standards
EN 60204–1
EN 55014–1: 2006 + A1: 2009
EN 55014–2: 1997 + A2: 2008
EN 61000–3–2: 2006 + A2: 2009
EN 61000–3–3: 2008
CE
O
Head of
A
pprobation
20
EN
Summary of Contents for WRP 3000 Comfort