12
English
19
Sleeve
20
Clamp sleeve (2 pieces)
21
Clamp elbow adapter female thread 1/4" (2 pieces)
22
Clamp elbow adapter female thread 3/8" (2 pieces)
23
Seal
24
*Sink
25
*Angle valve cold water inlet
26
*Flex hose
27
*Angle valve hot water inlet
28
*Worktop
29
Base
30
Filter cartridge
–
Pre-Pure filter 2.644-302.0 (left)
–
Hy-Protect filter 2.644-303.0 (centre)
–
Post-Protect filter 2.644-304.0 (right)
31
Clip
32
Label
33
Line 3/8"
34
Line 1/4"
35
Intake
36
Device WPC 120 UF
37
Recessed grip
*Not included in the scope of delivery.
Installing and connecting the device
ATTENTION
Only operate and store the device and its water-carrying
components in frost-free indoor areas.
몇
WARNING
Risk of material damage due to improper installa-
tion
Damage to sink / worktop and domestic plumbing as
well as damage caused by leaking water.
Only install the device and its components yourself if
you are capable of doing so and have the necessary
knowledge and tools.
If in doubt, have the device installed by a person with
professional knowledge.
After installation, be sure to check the tightness of the
entire system.
●
The water temperature and the water inlet pressure
must correspond to the specified values, see chap-
ter
.
ATTENTION
For higher line pressures, always connect an external
pressure reducer upstream!
●
Depending on local regulations, an approved back-
flow preventer must be installed.
●
Place the device on a flat, horizontal surface with the
base facing downwards.
●
The front cover and the stop valve must be freely ac-
cessible.
●
The distance to heat-radiating appliances such as
under-sink boilers or uninsulated hot water pipes
must be at least 100 mm.
●
Only connect the device with the lines provided.
●
Do not use lines that are used.
●
Do not bend the lines and do not subject them to
tension, torsion or compression.
●
Do not place any objects on the lines.
Connection diagram
1. Observe the connection diagram during installation:
Illustration C
Checking and adjusting the water inlet
pressure
1. Check the water inlet pressure at the pressure re-
ducer of the building's drinking water installation.
Under no circumstances may it exceed the maxi-
mum value specified in the Chapter
.
We recommend setting the water inlet pressure to
0.4 MPa (4 bar).
If there is no pressure reducer in the drinking water
installation of the building, a separate pressure re-
ducer must be connected upstream of the device.
If the value of the water inlet pressure cannot be de-
termined in the drinking water installation of the
building, a separate pressure reducer must be con-
nected upstream of the device.
Installing the tap
●
Select the installation position so that the tap is ac-
cessible for installation from below and the opening
of the outlet is above the sink.
Allow sufficient space for connecting the 1/4
″
line.
●
The material thickness A of the sink / worktop must
not exceed 24 mm. If the material thickness is high-
er, the worktop can be provided with a correspond-
ing countersink from below. If in doubt, have the
device installed by a person with professional
knowledge.
●
The upper and lower support surfaces must be flat
and parallel, with a diameter B of at least 50 mm.
Installation diagram
Illustration D
1. Drill a hole with a diameter C of 12 mm for the instal-
lation of the tap.
Use suitable drills or tools for the material of the sink
/ worktop.
Pre-drill if necessary.
2. Remove the protective film from the anchor plate.
3. Fit the anchor plate and the sealing washer on the
tap.
4. Insert the tap into the hole from above and align it.
5. Fit the washer from the bottom of the tap and tighten
the wing nut.
Installing the stop valve
몇
WARNING
Risk of damage due to excessive water temperature
Water with a temperature above 38° C irreversibly dam-
ages the filter cartridges.
Only connect the stop valve to the cold water inlet angle
valve, never to a hot water inlet angle valve.
Note
The corner valve for the cold water inlet is usually on the
right, an optional corner valve for the hot water inlet is
usually on the left.
1. Install the stop valve between the cold water inlet
angle valve and the flexible hose.
Illustration E
a Close the angle valve.