background image

English

31

6. Drain the water completely out of the steam boiler.

ATTENTION
Appliance damage due to descaler

An unsuitable descaler or incorrect dosing of the descal-
er may damage the appliance.
Only use KÄRCHER descaler.
Use 1 dosing unit of the descaler for 0.5 l water.
7. Apply descaler solution to the descaler according to

the details.

8. Fill the descaler solution into the steam boiler. Do 

not seal the steam boiler.

9. Allow the descaler solution to take effect for 

approx. 8 hours.

10. Drain descaler solution completely out of the steam 

boiler.

11. Repeat the descaling process if necessary.
12. Rinse the steam boiler 2-3 times with cold water in 

order to drain all the descaler solution residue.

13. Drain the water completely out of the steam boiler.
14. Dry the mounting for the grid connection cable.
15. Close the maintenance lock with an extension tube.

Care of accessories

(Accessories - depending on scope of delivery)

Note 

The floor cleaning cloth and the cover for the manual 
nozzle have been washed beforehand and can be used 
immediately for working with the appliance. The micro 
fibre cloths are not suitable for dryer.

Note 

When washing the cloths, observe the instructions on 
the washing tag. Do not use any liquid softeners as this 
will affect the ability of the cloths to pick up dirt.
1. Wash the floor cleaning cloths and covers at a max. 

temperature of 60 °C in the washing machine.

Troubleshooting guide

Malfunctions often have simple causes that you can 
remedy yourself using the following overview. When in 
doubt, or in the case of malfunctions not mentioned 
here, please contact your authorised Customer Service.

WARNING

Risk of electric shock and burns

Trying to eliminate faults while the appliance is connect-
ed to the mains or has not yet cooled down is always 
dangerous. 
Remove the mains plug.
Allow the appliance to cool down.

The water shortage indicator light flashes red and a 
signal tone sounds

No water in the tank.

Fill the water reservoir up to the “MAX” marking.

The water shortage indicator light is lit in red

No water in the steam boiler. The pump’s overheat pro-
tection has triggered.
1. Switch the device off; see Chapter Switch off the de-

vice.

2. Fill the water reservoir.
3. Switch on the device; see Chapter Switching on the 

device.

The water tank is not inserted correctly or is calcified.
1. Remove the water reservoir.
2. Rinse the water reservoir.
3. Insert the water reservoir and press downwards until 

it locks into place.

The steam lever cannot be pressed

The steam lever is locked with the child lock.

Set the child lock (selector switch for steam volume) 
to the front.
The steam lever is released.

Long heating-up time

The steam boiler is scaled.

Descale the steam boiler.

High water output

The steam boiler is scaled.

Descale the steam boiler.

The steam pressure iron “spits” water

Set the temperature controller to stage 

 .

Rinse or descale the steam boiler of the steam 
cleaner; see Chapter Descaling the steam boiler.

After ironing breaks, water droplets come out of the 
steam pressure iron

During longer ironing breaks, steam can condense in 
the steam line.

After pauses in the ironing process, direct the blast 
of steam onto a cloth until the steam flows evenly.

Technical data

Subject to technical modifications.

1.

2.

Electrical connection

Voltage

V

220

Phase

~

1

Frequency

Hz

50

Protection class

IPX4

Protection category

I

Performance data

Heating capacity

W

1850

Maximum operating pressure

MPa

0.35

Heating-up time

Minutes 4

Continuous steaming

g/min

50

Maximum steam blast

g/min

110

Filling quantity

Water reservoir

l

0.8

Steam boiler

l

0.5

Dimensions and weights

Weight (without accessories)

kg

4.1

Length

mm

350

Width

mm

280

Height

mm

270

Summary of Contents for SC 4 EasyFix Iron Plug

Page 1: ...SC 4 EasyFix Iron Plug SC 4 EasyFix Premium Iron Plug 59683160 07 18 2 English 17...

Page 2: ...2 l IEC 60364 1 l 3x1 mm...

Page 3: ...3 30 SC 1 SC 3 l 0 C SC 3...

Page 4: ...4 REACH www kaercher com REACH www kaercher com 4 4 4 4 4 4 5 6 7 8 11 11 13 14 14...

Page 5: ...5 K RCHER K RCHER...

Page 6: ...6 43 33 36 38 44...

Page 7: ...7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 2 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 2 31 2 32 33 34 35 2 36 37 38 39 40 41 42 43 44 1 2 3 1 2 1 2...

Page 8: ...8 4 5 6 a 1 b 2 1 7 1 2 3 50 1 2 1 2...

Page 9: ...9 1 2 50 MAX 3 1 50 MAX 60 1 2 3 4 5 3 1 2 MAX 0 8 l 2 1 MAX 0 8 l 1 2 1 2...

Page 10: ...10 3 50 1 50 MAX 1 2 3 4 5 6 10 1 2 3 4 5 6 7 1 2 1 3 4 5 1 2...

Page 11: ...11 6 7 8 9 1 10 20 cm 5 1 1 1 1 1 2...

Page 12: ...12 1 2 PVC 1 2 3 a b 1 1...

Page 13: ...13 5 1 2 3 1 2 K RCHER 1 50 2 3 4 K RCHER BE 6006 1 MAX 2 3 1 2 TF dH mmol l TF I 0 7 0 1 3 100 II 7 14 1 3 2 5 90 III 14 21 2 5 3 8 75 IV 21 3 8 50...

Page 14: ...14 1 2 3 4 5 6 K RCHER 0 5 7 8 9 8 10 11 12 13 14 15 1 60 C MAX 1 2 3 1 2 3 1 2 V 220 1 Hz 50 IPX4 I W 1850 MPa 0 35 4 g min 50 g min 110 l 0 8 l 0 5 kg 4 1 mm 350 mm 280 mm 270...

Page 15: ...15...

Page 16: ...16...

Page 17: ...and beware of third parties in particular children when work ing with the device Only peo ple who have been instructed on how to use the device or have proven their ability to operate it and have bee...

Page 18: ...he power supply and extension cable by running over it crush ing or yanking it or similar Pro tect the power supply cable from heat oil and sharp edges Un suitable electrical extension ca bles can be...

Page 19: ...mediately Only switch on the device when water is present in the steam boiler The device may other wise overheat see chapter Troubleshooting Accidents or damage due to the device falling over Before a...

Page 20: ...ds due to vibration In case of symptoms e g tingling in the fingers cold fingers take a break A general period of use cannot be set because this de pends on several influencing factors Personal tenden...

Page 21: ...free of cost provided that a material or manufac turing defect is the cause In a warranty case please contact your dealer with the purchase receipt or the next authorised customer service site See ov...

Page 22: ...glish Device description The maximum amount of equipment is described in these operating instructions Depending on the model used there are differences in the scope of delivery see packaging 43 33 36...

Page 23: ...23 Spotlight nozzle 24 Round brush small black 25 Round brush small yellow 26 Power nozzle 27 Round brush large 28 Steam turbo brush 29 Manual nozzle 30 Manual nozzle microfibre cover 2x 31 Extension...

Page 24: ...nnected Disconnecting accessories 1 Set the selector switch for the steam volume to the rear The steam lever is locked 2 Push the cover on the device socket down and dis connect the steam connector fr...

Page 25: ...er reservoir up to the MAX mark Switch on the device Note If there is no or too little water in the steam boiler the water pump starts to run and pumps water from the wa ter reservoir into the steam b...

Page 26: ...ves e g scents for filling 1 Fill the water tank with tap water or a mixture of tap water and no more than 50 distilled water up to the MAX mark The device is ready for use Switching off the device 1...

Page 27: ...or cleaning painted or plastic coated surfaces such as kitchen or living room furniture doors or parquet 1 To clean these surfaces steam a cloth briefly and use it to wipe over the surfaces Glass clea...

Page 28: ...he manual nozzle onto the steam gun accord ing to the spotlight nozzle 2 Pull the cover over the manual nozzle Steam turbo brush The steam turbo brush is set swinging by the emitted steam and is suite...

Page 29: ...as well as heat and moisture penetration can result in the carpet being damaged Prior to the application also check the heat resistance and impact of steam on the carpet at an insignificant spot usin...

Page 30: ...he selected range MAX As soon as the orange heating indicator light of the iron goes out ironing can be started 2 Press the steam switch top or the steam switch bottom Steaming at intervals Press the...

Page 31: ...he mains or has not yet cooled down is always dangerous Remove the mains plug Allow the appliance to cool down The water shortage indicator light flashes red and a signal tone sounds No water in the t...

Page 32: ...www kaercher com dealersearch Alfred K rcher SE Co KG Alfred K rcher Str 28 40 71364 Winnenden Germany Tel 49 7195 14 0 Fax 49 7195 14 2212...

Reviews: