10
English
5.906-513.0 Rev. 00 (12/10)
1 Flat fold filter
2 Air input
3 Air outlet
4 Suction turbine
5 Control chip
6 Power switch
7 ON/OFF switch, Tact filter cleaning system
8 Connecting cable for electric solenoid
9 Casing top, suction head
10 Container lock latch (2x)
11 Tact filter cleaning system
Disconnect the connecting cable for the electric
solenoid from the circuit board.
Pull out the connecting cable.
Replace the connecting cable.
Note
In order to avoid excessive pull on the connecting ca-
ble, the installation of the connecting cable must take
place with the filter lid open.
1 Connecting cable for electric solenoid
Insert a new connecting cable and connect it to the
circuit board and the electric solenoid. Route the
cables as shown in drawing (dotted line box).
Note
During placement of the hood make sure that no ca-
bles are crushed.
Install the hood in the reverse order.
1