Operating Instructions
KMR 1700 D
English
46
!
Unlatch the lamp mounting
closing bracket abd take out the
lamp bulb
!
To replace the lamp bulb in the
trafficator, remove the trafficator
glass from the trafficator casing.
Changing fuses
!
Open the rear engine covering
!
Swing-out and open the fusebox
!
Replacing blown fuses
Notes:
—
Replacement fuses (see
illustration)
—
Description (see inside of lid)
—
Use only fuses with the same
current rating
Lubricating the bearings
and cylinders
Tip cylinder
Stroke cylinder and thrust rod
Lubricating nipples are provided on
the bearings
Use a grease gun to lubricate them
The cylinder running surfaces must
be coated with a grease film
Battery safety instructions
Notes:
Observe the operating instructions
Work on batteries is permitted only
after instruction by trained personnel
Danger!
!
Wear safety goggles and
protective clothing
!
Observe regulations for the
prevention of accidents as well
as DIN VDE 0510, VDE 0105 T.1
Danger!
Risk of fire and explosion!
—
Smoking prohibited
—
No naked flames, glowing
embers or sparks in the vicinity of
batteries
—
Do not place any objects or tools
on the battery because voltage is
always present between the
battery poles
—
Areas in which batteries are
charged must be well ventilated,
as highly explosive gas forms
during charging
Danger of acid burns!
!
Rinse out or rinse off splashes of
acid in the eye or on the skin with
copious quantities of clean water
!
Then consult a doctor
immediately
!
Wash contaminated clothing with
water
—
Old batteries with this symbol are
reusable commodities and must
therefore be returned for
recycling
—
Old batteries which are not
returned for recycling must be
disposed of as special waste,
thereby observing all statutory
regulations
Removing and installing
battery
!
Unscrew negative pole lead
!
Unscrew positive pole lead
!
Unscrew the battery holder