background image

K 4 Full Control

Operating Instructions

Please read the operating instructions 
carefully before using the unit.

59667500 (11/15)

Summary of Contents for K 4 Full Control

Page 1: ...K 4 Full Control Operating Instructions Please read the operating instructions carefully before using the unit 59667500 11 15...

Page 2: ...2...

Page 3: ...3...

Page 4: ...leads to severe injuries or death WARNING Pointer to a possibly dangerous situation which can lead to se vere injuries or death CAUTION Pointer to a possibly dangerous situation which can lead to mi...

Page 5: ...intenance works Repair work and work on the electrical components may only be performed by an au thorised customer service WARNING The appliance may only be connected to an electric sup ply that has b...

Page 6: ...ated by children or per sons who have not been in structed accordingly This appliance is not intended for use by persons with limit ed physical sensory or men tal capacities or lacking expe rience and...

Page 7: ...Type BA Water that has flown through a system separator is no longer classified as drinking water High pressure hoses fixtures and couplings are important for the safety of the appli ance Only use hig...

Page 8: ...sure cleaners aerosols can develop Inhaling aerosols can cause health damage Depending on the applica tion completely shielded noz zles e g surface cleaner that significantly reduce the emission of a...

Page 9: ...or private households only for cleaning machines vehicles buildings tools facades terraces gardening tools etc by means of a high pressure water jet if necessary with ad ditional cleaning agents with...

Page 10: ...rigger gun ATTENTION Dry running of more than 2 minutes leads to damage of the high pressure pump If the appliance does not build up pressure within 2 minutes switch the appliance off and proceed in a...

Page 11: ...connections after opera tion Detach the appliance from the water supply CAUTION Risk of personal injury or damage Mind the weight of the appliance during transport Lift appliance by the carrying handl...

Page 12: ...vice checked by the customer service Voltage reduction due to weak mains supply or when using an extension cable Upon switch on push the lever of the trigger gun first and then switch the power switch...

Page 13: ...specifications Electrical connection Voltage 230 1 50 V Hz Connected load 1 8 kW Protection class IP X5 Protective class I Mains fuse slow blow 13 A Water connection Max feed pressure 1 2 MPa Max feed...

Page 14: ...14 English Use only original K RCHER spare parts Spare Parts...

Page 15: ...1 50 V Hz 1 8 kW IP X5 I 13 A 1 2 MPa 40 C 9 l min 0 5 m 11 MPa 13 MPa 6 3 l min 7 0 l min 0 3 l min 13 N 411 mm 305 mm 584 mm 12 8 kg EN 60335 2 79 K 4 2 0 9 m s2 m s2 LpA KpA 75 3 dB A dB A LWA KWA...

Page 16: ...0 OFF I ON Vario Power Mix Plug n Clean www kaercher com dealersearch...

Page 17: ...Plug n Clean Vario Power I ON 0 OFF AAA...

Page 18: ...Vario Power T K RCHER Plug n Clean Plug n Clean Plug n Clean Vario Power MIX MIX Plug n Clean 5 0 OFF 0 OFF HARD MEDIUM SOFT MIX...

Page 19: ...KARCHER 059 4 730 K RCHER K RCHER 2 643 100 I ON 30 90 I ON...

Page 20: ...KARCHER 1 2 13 7 5 KARCHER REACH www kaercher com REACH 3 PH 2...

Page 21: ...FFP 2 2 1 2 3 4 5 6 7 Plug n Clean 8 9 10 11 12 13 14 15 16 17 18 19 20 21 MIX 1 SOFT 2 MEDIUM 3 HARD 22 23 24 25 26 Vario Power 27 Plug n Clean 28...

Page 22: ...30 EN 12729 Typ BA...

Page 23: ...60 IEC 60364 I 30 1 10 1 5 m m 2 10 30 2 5 m m 2...

Page 24: ...K 4 Full Control 59667500 11 15...

Reviews: