background image

English

CAUTION

Safety installations serve the 

protection of the user and 

may not be modified or by-

passed.

The appliance switch prevents 

unintentional operation of the 

appliance.

This lock locks the lever of the 

trigger gun and prevents the in-

advertent start of the appliance.

If the lever on the trigger gun is 

released the pressure switch 

turns off the pump, the high 

pressure jet is stopped. If the le-

ver is pulled the pump is turned 

on again.

The motor protection switch 

switches off the device if the 

power consumption is high.

CAUTION

Wear protective clothing and 

safety goggles to protect 

against splash back contain-

ing water or dirt.

During the use of high-pres-

sure cleaners aerosols can 

develop. Inhaling aerosols 

can cause health damage.

Depending on the applica-

tion, completely shielded noz-

zles (e.g. surface cleaner) 

that significantly reduce the 

emission of aqueous aero-

sols can be used for high-

pressure cleaning.

The use of such shielding is 

not possible with all applica-

tions.

If the use of a completely 

shielded nozzle is not possi-

ble, a respirator of the catego-

ry FFP 2 or the like should be 

used, depending on the envi-

ronment to be cleaned.

Safety Devices

Power switch

Lock trigger gun

Overflow valve with pressure 

switch

Motor protection switch

Symbols on the machine

The high pressure jet 

must not be directed at 

persons, animals, live 

electrical equipment or at 

the appliance itself.

Gerät vor Frost schützen.
The appliance must not 

be directly connected to 

the public drinking water 

network.

Personal protective 

equipment

Summary of Contents for K 4 Full Control

Page 1: ...K 4 Full Control Operating Instructions Please read the operating instructions carefully before using the unit 59667500 11 15...

Page 2: ...2...

Page 3: ...3...

Page 4: ...leads to severe injuries or death WARNING Pointer to a possibly dangerous situation which can lead to se vere injuries or death CAUTION Pointer to a possibly dangerous situation which can lead to mi...

Page 5: ...intenance works Repair work and work on the electrical components may only be performed by an au thorised customer service WARNING The appliance may only be connected to an electric sup ply that has b...

Page 6: ...ated by children or per sons who have not been in structed accordingly This appliance is not intended for use by persons with limit ed physical sensory or men tal capacities or lacking expe rience and...

Page 7: ...Type BA Water that has flown through a system separator is no longer classified as drinking water High pressure hoses fixtures and couplings are important for the safety of the appli ance Only use hig...

Page 8: ...sure cleaners aerosols can develop Inhaling aerosols can cause health damage Depending on the applica tion completely shielded noz zles e g surface cleaner that significantly reduce the emission of a...

Page 9: ...or private households only for cleaning machines vehicles buildings tools facades terraces gardening tools etc by means of a high pressure water jet if necessary with ad ditional cleaning agents with...

Page 10: ...rigger gun ATTENTION Dry running of more than 2 minutes leads to damage of the high pressure pump If the appliance does not build up pressure within 2 minutes switch the appliance off and proceed in a...

Page 11: ...connections after opera tion Detach the appliance from the water supply CAUTION Risk of personal injury or damage Mind the weight of the appliance during transport Lift appliance by the carrying handl...

Page 12: ...vice checked by the customer service Voltage reduction due to weak mains supply or when using an extension cable Upon switch on push the lever of the trigger gun first and then switch the power switch...

Page 13: ...specifications Electrical connection Voltage 230 1 50 V Hz Connected load 1 8 kW Protection class IP X5 Protective class I Mains fuse slow blow 13 A Water connection Max feed pressure 1 2 MPa Max feed...

Page 14: ...14 English Use only original K RCHER spare parts Spare Parts...

Page 15: ...1 50 V Hz 1 8 kW IP X5 I 13 A 1 2 MPa 40 C 9 l min 0 5 m 11 MPa 13 MPa 6 3 l min 7 0 l min 0 3 l min 13 N 411 mm 305 mm 584 mm 12 8 kg EN 60335 2 79 K 4 2 0 9 m s2 m s2 LpA KpA 75 3 dB A dB A LWA KWA...

Page 16: ...0 OFF I ON Vario Power Mix Plug n Clean www kaercher com dealersearch...

Page 17: ...Plug n Clean Vario Power I ON 0 OFF AAA...

Page 18: ...Vario Power T K RCHER Plug n Clean Plug n Clean Plug n Clean Vario Power MIX MIX Plug n Clean 5 0 OFF 0 OFF HARD MEDIUM SOFT MIX...

Page 19: ...KARCHER 059 4 730 K RCHER K RCHER 2 643 100 I ON 30 90 I ON...

Page 20: ...KARCHER 1 2 13 7 5 KARCHER REACH www kaercher com REACH 3 PH 2...

Page 21: ...FFP 2 2 1 2 3 4 5 6 7 Plug n Clean 8 9 10 11 12 13 14 15 16 17 18 19 20 21 MIX 1 SOFT 2 MEDIUM 3 HARD 22 23 24 25 26 Vario Power 27 Plug n Clean 28...

Page 22: ...30 EN 12729 Typ BA...

Page 23: ...60 IEC 60364 I 30 1 10 1 5 m m 2 10 30 2 5 m m 2...

Page 24: ...K 4 Full Control 59667500 11 15...

Reviews: