5

OVERVIEW

Fig. 1
1 Swivel caster with parking brake
2 Connection for high-pressure hose
3 Fuel tank inlet
4 High-pressure hose
5 Cover latch
6 Handgun
7 Pressure gauge
8 Filler opening for cleaning agent
and metering equipment
9 Water connection 1 with strainer

Fig. 2
1 Selector switch ON/OFF and
   temperature

Indicator lamps
2 Fuel low
3 Ready for operation

Fig. 3
Press down cover latch with
screwdriver or coin and turn counter-
clockwise to open.
Turn clockwise to close.

Fig. 4
Compartment for accessories
beneath cover
10 Steam nozzle (4.766-023)
optional

COMMISSIONING

  Unit, piping, high-pressure hose

and connections must be in
perfect working order!

  Lock the hand brake.

Checking oil level

Fig. 5
Oil reservoir

Prior to initial startup, cut off tip of oil
reservoir cap
Contact KÄRCHER AFTER-SALES
SERVICE immediately if oil is
opaque!
If oil level is approaching MIN mark,
fill up with oil as far as MAX mark.
Seal oil filler inlet.
Refer to technical data for oil grade.

Filling with fuel

  Never operate unit with fuel tank

empty! Fuel pump would
otherwise be destroyed!

Fig. 6
Only fill with Kerosin.
Close tank cap
Wipe off excess fuel

Fill with cleaning agent

*

  Only use KÄRCHER products.

*

  Never pour in solvent (petrol,

acetone, thinner etc.)!

*

  Avoid contact with eyes and skin

*

  Pay attention to cleaning-agent

manufacturer's instructions on
safety and handling

KÄRCHER can provide an
individual range of cleaning and
treatment agents.
Your dealer will be pleased to advise
you.

Fig. 8
Fill with cleaning agent

Mounting handgun

  Connect spray lance to handgun

  Insert high-pressure nozzle in

union nut

  Mount and tighten unit nut

  Mount high-pressure hose at high-

pressure connection Fig. 1 Item 2

Water connection

For connected loads, refer to
Technical Data.
Mount supply hose at water
connection of unit.
Fig. 1 Item 9
(supply hose is not part of scope of
delivery)

Summary of Contents for HDS 796 CW

Page 1: ...HDS 796 CW www karcher com 5 959 421 09 99 1 173...

Page 2: ...HDS 796 CW 1 2 3 4 5 6 7 8 9 10 11 12...

Page 3: ...HDS 796 CW Operating Instructions 3 Spare Parts List 14 Prior to initial startup operating manual and safety instructions no 5 951 949 must be consulted...

Page 4: ...n 6 Switching on unit 6 Setting cleaning temperature 6 Measuring out cleaning agents 6 Intended use 7 Cleaning 7 Operation with cold water 7 Operation with hot water 7 After every operation 7 Shutting...

Page 5: ...e all times Follow te maintenance instructions specified in the manual This product must connected to a power supply receptacle protected by a GFCI ground fault circuit interrupter If Replacement Of T...

Page 6: ...ately if oil is opaque If oil level is approaching MIN mark fill up with oil as far as MAX mark Seal oil filler inlet Refer to technical data for oil grade Filling with fuel Never operate unit with fu...

Page 7: ...hould always be fully uncoiled and have an adequate cross section 10 m min 1 5 mm 2 30 m min 2 5 mm 2 OPERATION Never operate unit with fuel tank empty Fuel pump would otherwise be destroyed Switching...

Page 8: ...hot water Danger of scalding We recommend the following cleaning temperatures Slight contamination 86 122 F Protein soiling e g in foodstuffs industry max 140 F Motor vehicle cleaning machine cleanin...

Page 9: ...sconnect hose between water inlet and high pressure connection Fig 10 4 Connect high pressure hose with handgun Fig 1 5 Connect water inlet hose Fig 1 MAINTENANCE Disconnect unit from mains before car...

Page 10: ...ction hose Clean filter in water and re insert Change oil Provide a collecting container for approx 1 litres of oil Place drainage spout in position Loosen starting screw K RCHER tip Cut open RM 110 b...

Page 11: ...p Set selector switch to 0 and allow motor to cool down for at least 5 min Have unit checked by After Sales Service if this does not remedy fault Check mains connection power cord Bleed pump Set clean...

Page 12: ...r No ignition spark Soot deposits on heating coil Remedy 3 droplets min are permitted In the event of a major leak have unit checked by After Sales Service Check high pressure system and connections f...

Page 13: ...ure switch at the cylinder head to switch the pump back on again The overflow valve is set at the factory and sealed Adjustment can only be made by After Sales Service Safety valve The safety valve op...

Page 14: ...750 l h 750 l h Operating pressure cold hot water with standard nozzle supplied 100 MPa 100 bar 100 MPa 100 bar Operating temperature Hot water max 80 C max 80 C Steam Cleaning agent intake 0 12 l 0 1...

Page 15: ...HDS 796 CW 14...