Fault
                                                          
Unit leaking, water dripping out at
bottom

                                                          
Unit constantly switched on and
off with handgun closed
                                                          
Unit does not draw in cleaning
agent

                                                          
Burner not ignited

                                                          
Set temperature not attained
when working with hot water

Cause
                                                          

 Pump leaking

                                                          

  Leak in high-pressure system

                                                          

  Filter in cleaning-agent suction

hose dirty

  Non-return valve gummed up

                                                          

  Fuel tank empty

  Lack of water

  Fuel filter dirty

  Incorrect direction of rotation. If

direction of rotation is correct,
powerful jet of air will be felt at
exhaust-gas opening of burner.

  No ignition spark

                                                          

  Soot deposits on heating coil

Remedy
                                                          
3 droplets/min are permitted.
In the event of a major leak, have
unit checked by After-Sales Service.
                                                          
Check high-pressure system and
connections for leaks
                                                          
Clean filter
Pull off cleaning-agent hose and use
blunt object to release non-return
valve (see Fig.).
                                                          
Fill up
Check water connection, check
supply lines, clean low water
protection.
Replace fuel filter.
Check direction of rotation. If
necessary, have connection
replaced by a qualified electrician.

Have unit checked by After-Sales
Service if no ignition spark is visible
through inspection glass during
operation.
                                                          
Have After-Sales Service remove
soot deposits from unit

If fault cannot be rectified, have
unit checked by After-Sales
Service.

Summary of Contents for HDS 796 CW

Page 1: ...HDS 796 CW www karcher com 5 959 421 09 99 1 173...

Page 2: ...HDS 796 CW 1 2 3 4 5 6 7 8 9 10 11 12...

Page 3: ...HDS 796 CW Operating Instructions 3 Spare Parts List 14 Prior to initial startup operating manual and safety instructions no 5 951 949 must be consulted...

Page 4: ...n 6 Switching on unit 6 Setting cleaning temperature 6 Measuring out cleaning agents 6 Intended use 7 Cleaning 7 Operation with cold water 7 Operation with hot water 7 After every operation 7 Shutting...

Page 5: ...e all times Follow te maintenance instructions specified in the manual This product must connected to a power supply receptacle protected by a GFCI ground fault circuit interrupter If Replacement Of T...

Page 6: ...ately if oil is opaque If oil level is approaching MIN mark fill up with oil as far as MAX mark Seal oil filler inlet Refer to technical data for oil grade Filling with fuel Never operate unit with fu...

Page 7: ...hould always be fully uncoiled and have an adequate cross section 10 m min 1 5 mm 2 30 m min 2 5 mm 2 OPERATION Never operate unit with fuel tank empty Fuel pump would otherwise be destroyed Switching...

Page 8: ...hot water Danger of scalding We recommend the following cleaning temperatures Slight contamination 86 122 F Protein soiling e g in foodstuffs industry max 140 F Motor vehicle cleaning machine cleanin...

Page 9: ...sconnect hose between water inlet and high pressure connection Fig 10 4 Connect high pressure hose with handgun Fig 1 5 Connect water inlet hose Fig 1 MAINTENANCE Disconnect unit from mains before car...

Page 10: ...ction hose Clean filter in water and re insert Change oil Provide a collecting container for approx 1 litres of oil Place drainage spout in position Loosen starting screw K RCHER tip Cut open RM 110 b...

Page 11: ...p Set selector switch to 0 and allow motor to cool down for at least 5 min Have unit checked by After Sales Service if this does not remedy fault Check mains connection power cord Bleed pump Set clean...

Page 12: ...r No ignition spark Soot deposits on heating coil Remedy 3 droplets min are permitted In the event of a major leak have unit checked by After Sales Service Check high pressure system and connections f...

Page 13: ...ure switch at the cylinder head to switch the pump back on again The overflow valve is set at the factory and sealed Adjustment can only be made by After Sales Service Safety valve The safety valve op...

Page 14: ...750 l h 750 l h Operating pressure cold hot water with standard nozzle supplied 100 MPa 100 bar 100 MPa 100 bar Operating temperature Hot water max 80 C max 80 C Steam Cleaning agent intake 0 12 l 0 1...

Page 15: ...HDS 796 CW 14...

Reviews: