– 10
HDS 7/16
HDS 7/16
HDS 8/17
Main Supply
Voltage
V
400
230
400
230
Current type
Hz
3~ 50
3~ 50
3~ 50
3~ 50
Connected load
kW
4,7
4,7
5,7
5,7
Protection (slow)
A
16
16
16
16
Type of protection
--
IPX5
IPX5
IPX5
IPX5
Protective class
--
I
I
I
I
Maximum allowed net impedance
Ohm
--
--
0.2638
Water connection
Max. feed temperature
°C
30
30
30
Min. feed volume
l/h (l/min)
900 (15)
900 (15)
1000 (16,7)
Suck height from open container (20 °C)
m
0,5
0,5
0,5
Max. feed pressure
MPa (bar)
1 (10)
1 (10)
1 (10)
Performance data
Water flow rate
l/h (l/min)
270-660 (4,5-
11)
270-660 (4,5-
11)
290-760 (4,8-
12,7)
Operating pressure of water (using standard noz-
zle)
MPa (bar)
3-16 (30-160)
3-16 (30-160)
3-17 (30-170)
Max. excess operating pressure (safety valve)
MPa (bar)
19,5 (195)
19,5 (195)
20,5 (205)
Max. operating temperature of hot water
°C
98
98
98
Detergent suck in
l/h (l/min)
0-39,6 (0-0,66) 0-39,6 (0-0,66) 0-45,6 (0-0,76)
Burner performance
kW
43
43
51
Maximum consumption of heating oil
kg/h
4,1
4,1
4,7
Max. recoil force of trigger gun
N
32,4
32,4
39,8
Size of standard nozzle
--
040
040
045
Values determined as per EN 60335-2-79
Noise emission
Sound pressure level L
pA
dB(A)
77
77
79
Uncertainty K
pA
dB(A)
3
3
3
Sound power level L
WA
+ Uncertainty K
WA
dB(A)
95
95
96
Hand-arm vibration value
Hand spray gun
m/s
2
2,6
2,6
2,0
Spray lance
m/s
2
4,2
4,2
2,7
Uncertainty K
m/s
2
0,3
0,3
0,3
Fuel
Fuel
--
Fuel oil EL or
Diesel
Fuel oil EL or
Diesel
Fuel oil EL or
Diesel
Amount of oil
l
0,3
0,3
0,3
Oil grade
--
SAE 90
SAE 90
SAE 90
Dimensions and weights
Length x width x height
mm
1060 x 650 x
920
1060 x 650 x
920
1060 x 650 x
920
Typical operating weight, C
kg
118,1
118,1
121,1
Typical operating weight, CX
kg
121
121
124
Fuel tank
l
15,5
15,5
15,5
Detergent Tank
l
15,5
15,5
15,5
26
EN