III. Operation

1. Initial operation (cold-water mode)

– Open water inlet.

– Unit switch to position “SYMBOL Burner off”.

– Start engine according to operating instructions.

– Retract lever of handgun.

The pump first extracts air out of the unit. After a short time water will come out of the nozzle.

Caution!

The water jet being emitted effects a recoil force or torque on the handgun,
so grip the handgun firmly.

– If during operation you release the lever of the handgun, the overflow valve will open and a water

circulation will take place inside the pump. At the same time, the revolutions per minute of the engine
will be reduced from operating speed to idling speed by the speed regulator fitted to the cylinder head.

– The switch-over pressure of approx. 240 bar remains in the system between overflow valve and

handgun.

– A further retraction of the lever releases this pressure, the overflow valve closes, the engine

accelerates to operating speed and the spraying pressure is reasserted.

2. Hot water mode

– Set the temperature regulator to the desired working temperature, the maximum being 98 °C. The

burner is thereby switched on. At a maximum demand on the pump, the water temperature rises in
accordance with the setting on the thermostat, but not above 98 °C.

3. Regulate pressure and water flow

The unit is fitted with a servopress device. Operating pressure and rate of flow can be infinitely adjusted
by the regulator wheel on the handgun. The temperature regulator may be set to a maximum of 98 °C.

4. Steam stage mode

If the temperature regulator is to be set higher than 98 °C, the nozzle on the spray lance should be
exchanged for a steam nozzle.
– Set the temperature regulator to 150 °C.
– Set the regulator wheel on the handgun to MIN stop position.

5. Spraying with cleaning agent

– Hang the cleaning agent hose with filter into container of cleaning agent.

– The proportion of cleaning agent in the water flow can be adjusted infinitely up to a rate of

approx. 5 %.

Cleaning methods

a) Single-step method

Spray on the cleaning agent with high pressure.

b) Two-step method

Spray on the cleaning agent with low pressure and leave it to take effect (1 – 5 minutes).
Spray away the dirt with the high-pressure water jet (without cleaning agent).

Summary of Contents for HDS 1000 DE

Page 1: ...5 959 083 06 01 HDS 1000 DE...

Page 2: ......

Page 3: ...S 1000 DE 3 E N G L I S H Contents I Technical data 4 II Important notes 6 III Operation 8 IV Application 9 V Care and maintenance 10 VI Trouble shooting 12 VII General Notes 14 VIII Spare parts list...

Page 4: ...ater inlet volume l h 1000 Flow rate l h 450 900 Flow rate steam stage l h 450 Temperature Max feed temperature C 30 Max working temperature high pressure stage C 98 Permissible working temperature st...

Page 5: ...ulation 14 Pulsationdamper 15 Fuelpump 16 Blower 17 Electrical box 18 Oil sight glass pump 19 Safetyvalve 20 Burnercover 21 Continuous flowheater 22 Spark plugconnector 23 Sight glass 24 Tuyereconnect...

Page 6: ...level of the engine Do not put the machine into operation if the oil level has sunk below MIN Top up with oil as required Care of the battery The battery has been filled and charged at the factory If...

Page 7: ...d area protected from frost Action of the safety devices Low water protection The low water protection device stops the burner from switching on when there is insufficient water When there is sufficie...

Page 8: ...ure regulator to the desired working temperature the maximum being 98 C The burner is thereby switched on At a maximum demand on the pump the water temperature rises in accordance with the setting on...

Page 9: ...e nozzle and is limited by the switch off pressure of the overflow valve as indicated above Apart from the working pressure and the distance from the object being cleaned the form of the jet determine...

Page 10: ...050 1 litre 3 Decarbonising the heating coil Undo all connections to the boiler cover cloth seal spark plug connector fuel line fastening screws The boiler is entirely disassembled and the heating coi...

Page 11: ...he use of an alkaline solution e g RM 81 to be pumped through the unit via the detergent tank to provide protection against corrosion and to neutralise the acid residue 5 Repairs The safety valve is a...

Page 12: ...unit with opened handgun if necessary repeat procedure Call in Customer Service Call in Customer Service Open water tap Check and seal Dismantle strainer and clean it Call in Customer Service Fill up...

Page 13: ...s cleaning agent metering valve leaking or blocked Clean or fill up Check and clean 6 Flow protection does not switch on no flame a b c d e Water supply valve closed Insufficient water Strainer in fro...

Page 14: ...ions must be checked once a year for its adherence to emission control values by your area chimney sweep responsible for such tasks The operator of the high pressure cleaner must arrange for the measu...

Page 15: ...042 402 0 1 811 936 0 HDS 1000 DE 6 491 261 0 6 491 262 0 10 12 1999 5 826 020 0 5 826 020 0 6 654 026 0 5 045 211 0 6 654 074 0 4 820 946 0 6 654 075 0 4 820 732 0 4 760 355 0 6 303 025 0 5 321 493...