background image

14

HDS 1000 DE

VII. General Notes

1. System test pressure and design accord with the statutory regulations for steam boilers.

2. The “Richtlinien für Flüssigkeitsstrahler” (Guidelines for liquid jets) issued by the Verband der

gewerblichen Berufsgenossenschaften, available from Carl Heymanns-Verlag KG, Luxemburger
Str. 449, 5000 Köln 41, apply in the Federal Republic of Germany.

3. In accordance with the “Richtlinien der Flüssigkeitsstrahler” (paragraph VI.1.), high-pressure jets

must be inspected at least every 12 months by an expert; the results of the inspection must be put
in writing.

Kärcher Customer Service maintenance engineers are experts and can carry out this prescribed
inspection at your premises.

4. The volume of water in the unit amounts to less than 10 litres. The unit is therefore subject to no

installation regulations as far as the boiler is concerned. When operating with temperatures of over
100 °C in unsupervised operation, the burner must be fitted with a flame monitoring system.
Regulations of the local building authorities should be observed.

5. The heating facility is a furnace which, according to the first ordinance for the implementation of the

Federal law on the protection against noxious emissions, must be checked once a year for its
adherence to emission control values by your area chimney sweep responsible for such tasks. The
operator of the high-pressure cleaner must arrange for the measurement to take place.

6. Safety inspection agreement

You can enter into a safety inspection agreement with Kärcher. This includes the inspection with
inspection badge and inspection record as required under VII.3. and VII.5.

7. Maintenance agreement

You can also enter into a maintenance agreement with Kärcher. It involves all the care and
maintenance operations as in V.1. Maintenance Schedule. The maintenance agreement contains in
it the safety inspection agreement.

8. Accessories

Wrong, unsuitable or defective accessories impair the functioning of your Kärcher unit. Their use is
dangerous. Ask us or your dealer about suitable and tested accessories. A Kärcher original
accessory is practical and tailor-made.

9. Spare parts

Be aware that the use of other than original spare parts can lead to the occurrence of faults and also
to bad accidents when these parts have not been manufactured properly, or when they do not exactly
replace the original part. They can also make the operation of  the unit unreliable.

Original spare parts offer the guarantee that you will always be able to operate your unit safely and
free of faults.

You will find the numbers of a selection of the most commonly required replacement parts on the back
cover.

Summary of Contents for HDS 1000 DE

Page 1: ...5 959 083 06 01 HDS 1000 DE...

Page 2: ......

Page 3: ...S 1000 DE 3 E N G L I S H Contents I Technical data 4 II Important notes 6 III Operation 8 IV Application 9 V Care and maintenance 10 VI Trouble shooting 12 VII General Notes 14 VIII Spare parts list...

Page 4: ...ater inlet volume l h 1000 Flow rate l h 450 900 Flow rate steam stage l h 450 Temperature Max feed temperature C 30 Max working temperature high pressure stage C 98 Permissible working temperature st...

Page 5: ...ulation 14 Pulsationdamper 15 Fuelpump 16 Blower 17 Electrical box 18 Oil sight glass pump 19 Safetyvalve 20 Burnercover 21 Continuous flowheater 22 Spark plugconnector 23 Sight glass 24 Tuyereconnect...

Page 6: ...level of the engine Do not put the machine into operation if the oil level has sunk below MIN Top up with oil as required Care of the battery The battery has been filled and charged at the factory If...

Page 7: ...d area protected from frost Action of the safety devices Low water protection The low water protection device stops the burner from switching on when there is insufficient water When there is sufficie...

Page 8: ...ure regulator to the desired working temperature the maximum being 98 C The burner is thereby switched on At a maximum demand on the pump the water temperature rises in accordance with the setting on...

Page 9: ...e nozzle and is limited by the switch off pressure of the overflow valve as indicated above Apart from the working pressure and the distance from the object being cleaned the form of the jet determine...

Page 10: ...050 1 litre 3 Decarbonising the heating coil Undo all connections to the boiler cover cloth seal spark plug connector fuel line fastening screws The boiler is entirely disassembled and the heating coi...

Page 11: ...he use of an alkaline solution e g RM 81 to be pumped through the unit via the detergent tank to provide protection against corrosion and to neutralise the acid residue 5 Repairs The safety valve is a...

Page 12: ...unit with opened handgun if necessary repeat procedure Call in Customer Service Call in Customer Service Open water tap Check and seal Dismantle strainer and clean it Call in Customer Service Fill up...

Page 13: ...s cleaning agent metering valve leaking or blocked Clean or fill up Check and clean 6 Flow protection does not switch on no flame a b c d e Water supply valve closed Insufficient water Strainer in fro...

Page 14: ...ions must be checked once a year for its adherence to emission control values by your area chimney sweep responsible for such tasks The operator of the high pressure cleaner must arrange for the measu...

Page 15: ...042 402 0 1 811 936 0 HDS 1000 DE 6 491 261 0 6 491 262 0 10 12 1999 5 826 020 0 5 826 020 0 6 654 026 0 5 045 211 0 6 654 074 0 4 820 946 0 6 654 075 0 4 820 732 0 4 760 355 0 6 303 025 0 5 321 493...

Reviews: