English
23
Oil change:
Î
Ready a catch bin for appr. 1 Liter oil.
Î
Turn out the oil drain screw.
Î
Drain the oil in a collection basin.
Î
Turn out the oil drain screw.
Î
Slowly fill in new oil until the "MAX" mark-
ing on the oil dipstick.
Note
Air pockets must be able to leak out.
For oil type refer to technical specifica-
tions.
몇
Warning
Risk of damage! Freezing water in the appli-
ance can destroy parts of the appliance.
Store the appliance in a heated room during
winter or empty it. During longer breaks in
operation, it is advisable to pump in anti-frost
agents into the appliance.
Î
Screw off water supply hose and high
pressure hose.
Î
Operate device for max. 1 minute until
the pump and conduits are empty.
Note
Observe handling instructions of the anti-
freeze agent manufacturer.
Î
Pump in conventional frost protection
agents through the appliance.
A certain corrosion protection is achieved
with this as well.
Î
Park the machine on an even surface.
Î
Connect air pressure testing device to
tyre valve.
Î
Check air pressure and adjust if re-
quired.
Î
Set air pressure for the front and rear
tyres at max. 1.5 bar.
You can rectify minor faults yourself with the
help of the following overview.
If in doubt, please consult the authorized
customer service.
Risk of injury
Always switch off the appliance and pull out
the mains plug before care and maintenance
work.
Warning
Repair works may only be performed by the
authorized customer service.
– No power
Î
Check whether the voltage indicated on
the type plate corresponds to the voltage
of the socket.
Î
Check the mains connection cable for
damages.
– Motor overloaded; the motor protection
switch has got triggered
Î
Turn off the appliance.
Î
Disconnect the mains connection cable.
Î
Open the electrical box.
Î
Turn on the motor protection switch
again.
Î
Close the electrical box.
Î
Turn on the appliance.
– Protective motor switch has got triggered
again
Î
Get the device checked by Customer
Service.
– Wrong nozzle
High-pressure pump
Dispose of old oil ecologically or turn it in
at a collection point.
Frost protection
Drain water
Flush device with anti-freeze agent
Check the tyre pressure
Troubleshooting
Appliance is not running
Device is not building up pressure
Summary of Contents for HD 11/35 Ec-B Cage
Page 2: ...2...
Page 3: ...3...
Page 4: ...4...
Page 129: ...129 K rcher...
Page 130: ...130...
Page 131: ...131 A T IEC 60364 1 1 10 m 4 mm2 10 30 m 6 mm2 T 1 A2 Karcher 6 412 578 1 m...
Page 132: ...132 1 30 cm...
Page 133: ...133 Power 25 25 80 C 2 3 2 3 0 Power...
Page 134: ...134 50 500 800...
Page 135: ...135 1 MAX 1 1 5 bar...
Page 136: ...136 Elektrokasten schlie en 3...
Page 137: ...137 www kaercher com Carl Heymanns Verlag KG 50939K ln Luxemburger Stra e449 BGR 500 12...
Page 152: ...152 ycc 11 12 13 14 15 16 17 18 19 20 K rcher...
Page 153: ...ycc 153...
Page 154: ...154 ycc MIN Power IEC 60364 1 1 10 4 2 10 30 6 2 1 2 K rcher 6 412 578...
Page 155: ...ycc 155 1 1 30...
Page 156: ...156 ycc I Power 25 25 80 C 2 3 2 3 0 Power...
Page 157: ...ycc 157...
Page 158: ...158 ycc 50 500 800...
Page 159: ...ycc 159 1 MAX 1 1 5...
Page 160: ...160 ycc 3...
Page 258: ...258...
Page 259: ...259...
Page 260: ...260 MIN A C IEC 60364 1 1 10 4 2 10 30 6 2 1 2 6 412 578...
Page 261: ...261 1 1 30...
Page 262: ...262 I 25 25 80 C 2 3 2 3 0...
Page 263: ...263...
Page 264: ...264 50 500 800...
Page 265: ...265 1 MAX 1 1 5 bar...
Page 266: ...266 3...
Page 270: ......